THOMA * Illustration of deficiencies in scanning and storage process *
Image quality in this process * Different costs entailed by better image
quality * Techniques for overcoming various de-ficiencies: fixed
thresholding, dynamic thresholding, dithering, image merge * Page edge
effects *
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
George THOMA, chief, Communications Engineering Branch, National Library
of Medicine (NLM), illustrated several of the deficiencies discussed by
the previous speakers. He introduced the topic of special problems by
noting the advantages of electronic imaging. For example, it is regenerable
because it is a coded file, and real-time quality control is possible with
electronic capture, whereas in photographic capture it is not.
One of the difficulties discussed in the scanning and storage process was
image quality which, without belaboring the obvious, means different
things for maps, medical X-rays, or broadcast television. In the case of
documents, THOMA said, image quality boils down to legibility of the
textual parts, and fidelity in the case of gray or color photo print-type
material. Legibility boils down to scan density, the standard in most
cases being 300 dpi. Increasing the resolution with scanners that
perform 600 or 1200 dpi, however, comes at a cost.
Better image quality entails at least four different kinds of costs: 1)
equipment costs, because the CCD (i.e., charge-couple device) with
greater number of elements costs more; 2) time costs that translate to
the actual capture costs, because manual labor is involved (the time is
also dependent on the fact that more data has to be moved around in the
machine in the scanning or network devices that perform the scanning as
well as the storage); 3) media costs, because at high resolutions larger
files have to be stored; and 4) transmission costs, because there is just
more data to be transmitted.
But while resolution takes care of the issue of legibility in image
quality, other deficiencies have to do with contrast and elements on the
page scanned or the image that needed to be removed or clarified. Thus,
THOMA proceeded to illustrate various deficiencies, how they are
manifested, and several techniques to overcome them.
Fixed thresholding was the first technique described, suitable for
black-and-white text, when the contrast does not vary over the page. One
can have many different threshold levels in scanning devices. Thus,
THOMA offered an example of extremely poor contrast, which resulted from
the fact that the stock was a heavy red. This is the sort of image that
when microfilmed fails to provide any legibility whatsoever. Fixed
thresholding is the way to change the black-to-red contrast to the
desired black-to-white contrast.