Except when otherwise stated, all titrations should be made at the
ordinary temperature; cooling, if necessary, by holding the flask under
the tap. When a titration is directed to be made in a boiling solution,
it must be remembered that the standard solution is cold, and that every
addition lowers the temperature of the assay.
On running the solution from the burette into the assay, do not let it
run down the side of the flask. If a portion of the assay has to be
withdrawn for testing, shake the flask to ensure mixing, and then take
out a drop with the test-rod; the neglect of these precautions may give
a finishing-point too early. This is generally indicated by a sudden
finish, in which case on shaking the flask and again testing no reaction
is got. Do not remove the drop on the point of the burette with the
test-rod; let it remain where it is or drop it into the solution by
carefully opening the clip.
Generally the methods of working are as follows:--
(1) _When the finishing-point depends on a change of colour in the
solution._--Increase the bulk of the assay up to from 100 to 150 c.c.
with water. Boil or cool, as the case may be. Run in the standard
solution from a burette speedily, until the re-agent appears to have a
slower action, and shake or stir all the time. Then run 1 c.c. or so at
a time, still stirring, and finally add drops until the colour change is
got.
(2) _When an outside-indicator is used._--Pour the standard solution
from a burette into the assay until 5 or 6 c.c. from the
finishing-point; then run in 1 c.c. at a time (stirring and testing on
the plate between each) until the indicator shows the change wanted, and
deduct 0.5 c.c. for excess. When greater accuracy is sought for a
duplicate assay is made. In this case the standard solution is run in
close up to the end, and the operation is finished off with a few drops
at a time.
(3) _Where the finishing-point depends upon the absence of a precipitate
and no outside-indicator is used._--As in the last case, run in the
standard solution up to within a few c.c. of the end, then run in 1 c.c.
at a time until a precipitate is no longer formed, but here 1.5 c.c.
must be deducted for excess, since it is evident that the whole of the
last "c.c." must have been, and a portion of the previous one may have
been, in excess.