We have in sewers and drains a power created by the influx of the sewage
which is greater than any mechanical means that can be used in the
ventilation of them, and it is to get the best method of applying this
power that sanitary engineers must direct their attention.
The difficulties that are met with in ventilating sewers with open
gratings are so great, that I am convinced that as soon as engineers
study the question more fully, the system will be abandoned.
The method of carrying off the soil by water through sewers has proved a
good and convenient one, and scarcely any defect can be found in any
drainage scheme except that of the ventilation, which is at present one
that is condemned by the inhabitants of most towns as a nuisance,
especially in hot weather, and by the medical profession as being most
prejudicial to health.
As a remedy for this, we must profit by the experience of the early
experiments I have quoted, which points conclusively to the fact that if
we extract from the gas (which by compression must of necessity leave
the sewers at openings) the noxious and disease-producing poisons
contained in it, at the gratings, and by those means prevent a rapid
decomposition of the sewage taking place, and without putting any undue
pressure on the water-seals to houses, we have overcome the greatest
difficulty in the work.
In old drains or sewers it will be the work of some time for the
surveyor to know that each drain from the house to the main sewer is
trapped with a good water-seal, yet this is the most important factor in
providing good ventilation.
Some persons have hastily condemned the water-trap, having found out
that they have been siphoned by the transit of the sewage. This is a
mistake. A properly constructed water-seal or trap that clears itself at
each flushing is the best seal for sewer gas. It will not keep out gas
if it is forced in bulk by excessive pressure, any more than coal gas
can be kept out of houses if a greater pressure is put on at the works
than the resistance of the trap in the chandelier. In manufacturing gas,
either experimentally or otherwise, water is the seal always used, but
we do not attach anything to break that seal when dealing with gas for
illuminating purposes, the same as is done in many cases with sewers.
Where new drains are laid, no difficulty in getting a good seal to
branch drains need be experienced, and no drain from the house to sewers
should be laid without its being completely disconnected or cut off as
near the soil-pipe as possible.
In dealing with the ventilation of soil-pipes or vertical drains, many
improvements can in future be made. The idea of carrying tall
ventilating pipes to the tops of houses was to carry off gas that was
forced in bulk through the trap at the bottom of the soil-pipe from the
sewer, but in well-laid drains this should never occur. If the drain be
disconnected it would leave at the point of disconnection.