The final test of the canister is always carried out by means of the
so-called “man test.” Special man-test laboratories were built at
Washington, Philadelphia and Long Island. These are so constructed
that, if necessary, a man may enter the chamber containing the gas and
thus test the efficiency of the completed gas mask. In most cases,
however, the canister is placed inside or outside the gas-chamber and
the men breathe through the canister, detecting the break point by
throat and lung irritation.
The following brief description of the man test laboratory at the
American University will give a good idea of the plan and procedure.[32]
[Footnote 32: Taken from Fieldner’s article mentioned above.]
The man test laboratory is a one-story building, 56 ft. in length and
25 ft. in width. The main part is occupied by three gas chambers,
laboratory tables, and various devices for putting up and controlling
gas concentrations in the chambers. A small part at one end is used as
an office and storeroom.
Good ventilation is of great importance in a laboratory of this nature.
This is secured by means of a 6 ft. fan connected to suitable ducts.
The fan is mounted on a heavy framework outside and at one end of the
building. The fan is driven at a speed of about 250 r.p.m. by a 10 h.p.
motor. The main duct is 33 in. square, extending to all parts of the
building. A connection is also made to a small hood used when making
chemical analyses.
The gases, fumes, etc., drawn out by the fan, are forced up and out of
a stack 30 in. in diameter, extending upward 55 ft. above the ground
level.
The main features of each of the three gas chambers are identical.
Auxiliary pieces of apparatus are used with each chamber, the type of
apparatus being determined by the characteristics of the gas employed.
[Illustration: FIG. 76.—Man Test Laboratory, American University.]
Each chamber is 10 ft. long, 8 ft. wide and 8½ ft. high, having,
therefore, a capacity of 680 cu. ft. or 19,257 liters. The floor is
concrete, and the walls and ceiling are constructed on a framework
of 2 × 4 in. scantling, finished on the outside with wainscoting and
on the inside with two layers of Upson board (laid with the joints
lapped) covered with a ½ in. layer of special cement plaster laid upon
expanded metal lath. The interior finish is completed by two coats of
acid-proof white paint. The single entrance to the chamber is from
outside the laboratory, and is closed by two doors, with a 36 × 40 in.
lock between them. These doors are solid, of 3-ply construction, 2½ in.
thick, with refrigerator handles, which may be operated from either
inside or outside the chamber. The door jambs are lined with ³/₁₆ in.
heavy rubber tubing to secure a tight seal.
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Elsewhere in the archive
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account