At the end of the chamber opposite the doors, a pane of ¼ in. wire
plate glass, 36 × 48 in., is set into the wall, and additional
illumination may be secured by 2 headlights, 12 in. square, set into
the ceiling of the chamber and of the air-lock, respectively, and
provided with 200 watt Mazda lamps and Holophane reflectors. Openings
into the chamber, five in number, are spaced across this end beneath
the window and 9 in. above the table top.
Fans are installed for keeping the concentration uniform.
[Illustration: FIG. 77.—Details of Canister Holder.]
Various devices have been installed for attaching the canister to be
tested (Fig. 77). This arrangement allows the canister to be changed at
will without any necessity for disturbing the concentration of gas by
entering the chamber.
Arrangements for removing the gas from the chamber consist of a small
“bleeder” which allows a continuous escape of small amounts and a large
blower for rapidly exhausting the entire contents of the chamber.
Other general features of the equipment deal with the determination
of the physical condition surrounding the tests, often a matter of
considerable importance. The temperature of the gas inside the chamber
is easily ascertained by means of a thermometer suspended inside the
window in such a position as to be read from the outside. The relative
humidity of the mixture of air and gas in the chamber is determined by
means of a somewhat modified Regnault dew point apparatus mounted on
the built-in table.
PRESSURE DROP AND LEAK DETECTING APPARATUS
Another piece of apparatus consists of a combined pressure drop machine
and leak tester (Fig. 78) for measuring the resistance of canisters
and testing them for faulty construction. This is mounted on a small
table, with the motor and air pump installed on a shelf underneath.
The resistance, or pressure drop, of canisters is measured by the
flow meter _A_ and the water manometer _B_. Air is drawn through the
canister and the flow meter _A_ at the rate of 85 liters per min.,
the flow being adjusted by the needle valve. The pressure drop across
the canister is read on the water manometer _B_, one end of which is
connected to the suction line, the other open to the air. The reading
is generally made in inches, correction being made for the resistance
of the connecting hose and the apparatus itself.