Draining for Profit, and Draining for Health — John Shaqi
Draining for Profit, and Draining for HealthWaring, George E. (George Edwin)
Science
Draining for Profit, and Draining for Health
Waring, George E. (George Edwin)
Drain-tiles; Drainage
"I found iron-sand rocks, strong clay, silt, iron, etc., and an
enormous quantity of water, all _below_ the 2-foot drains. This
accounted at once for the sudden check the crops always met with
in May, when they wanted to send their roots down, but could not,
without going into stagnant water."
"There can be no doubt that it is the _depth_ of the drain which
regulates the escape of the surface water in a given time; regard
being had, as respects extreme distances, to the nature of the
soil, and a due capacity of the pipe. _The deeper the drain, even
in the strongest soils, the quicker the water escapes._ This is an
astounding but certain fact.
"That deep and distant drains, where a sufficient fall can be
obtained, are by far the most profitable, by affording to the
roots of the plants a greater range for food."
Of course, where the soil is underlaid by rock, less than four feet from
the surface; and where an outlet at that depth cannot be obtained, we
must, per force, drain less deeply, but where there exists no such
obstacle, drains should be laid at a _general_ depth of
four-feet,—general, not uniform, because the drain should have a uniform
inclination, which the surface of the land rarely has.
*The Distance between the Drains.*—Concerning this, there is less
unanimity of opinion among engineers, than prevails with regard to the
question of depth.
In tolerably porous soils, it is generally conceded that 40 or even 50
feet is sufficiently near for 4-foot drains, but, for the more retentive
clays, all distances from 18 feet to 50 feet are recommended, though those
who belong to the more narrow school are, as a rule, extending the limit,
as they see, in practice, the complete manner in which drains at wider
intervals perform their work. A careful consideration of the experience of
the past twenty years, and of the arguments of writers on drainage, leads
to the belief that there are few soils, which need draining at all, on
which it will be safe to place 4-foot drains at much wider intervals than
40 feet. In the lighter loams there are many instances of the successful
application of Professor Mapes’ rule, that "3-foot drains should be placed
20 feet apart, and for each additional foot in depth the distance may be
doubled; for instance, 4-foot drains should be 40 feet apart, and 5-foot
drains 80 feet apart." But, with reference to the greater distance, (80
feet,) it is not to be recommended in stiff clays, for any depth of drain.
Where it is necessary, by reason of insufficient fall, or of underground
rock, to go only three feet deep, the drains should be as near together as
20 feet.