Elements of Trench WarfareWaldron, William H. (William Henry)
History
Elements of Trench Warfare
Waldron, William H. (William Henry)
Intrenchments; Siege warfare
The enemy is always listening for indications of the direction and
position of gallery heads. Work must therefore be carried on with a
minimum of noise. Shouting down the shafts of galleries is absolutely
forbidden.
When the mining operations of the enemy are detected a report should be
made at once to the officer in charge of that section of the trench.
CHAPTER IV
Field Trenches
The next element of the defensive position is the _first line fire
trenches_. These are located so as to have a good field of fire to
the front for several hundred yards and so constructed as to give the
greatest cover and protection from the fire of the enemy.
An unbroken, continuous trench would be exposed to enfilade fire. A
shell, shrapnel or grenade bursting therein would have widespread
effect. To overcome these elements the trench is constructed in short
lengths, with traverses between them, and technically known as the
_traverse type_.
Better defilade is thus secured and the material effect of any burst is
confined to narrow limits.
The trench interval between the traverses is known as the “bay,” which
should not ordinarily be longer than 18 feet. Longer bays invite heavy
casualties in case the trench is enfiladed or a high explosive shell
finds its mark.
The illustration, Plate 14, shows a trace of the traversed type of fire
trench.
[Illustration: _PLAN OF TRAVERSED TYPE OF FIRE TRENCH_
_PLATE 14._
1. Length of bay, 18 feet.
2. Width of traverse, 5 feet.
3. Length of traverse, 5 feet.
4. Overlap of traverse, 3 feet.
5. Height of traverse depends upon defilade required and
practicability of concealment.
]
Type of Trench
Formerly, protection from the enemy’s fire was obtained by thickness of
parapet. In the trench warfare of today it is obtained by completely
concealing the riflemen in a deep, narrow trench with a very low
parapet.
The height over which the average man can fire is about 5 feet or about
five-sixths of his own height. This factor determines the height of the
parapet above the firing banquet of the trench or the height of bottom
of loophole above the same point, when the latter is employed.
The type of trench in general use today is the simple standing trench
shown in Plate 15.
[Illustration:
PLATE 15.—Simple standing trench. 1. Width at top, 3 feet 4 inches.
2. Width at bottom, over all, 2 feet 8 inches. 3. Width of firing
banquet, 1 foot 4 inches. 4. Height of parapet above firing banquet, 5
feet. 5. Height of parapet above bottom of trench, 6 feet 4 inches.
]
[Illustration: _PLATE 15a._
_Type of_
_INSTRUCTION FIRE TRENCH AT VALCARTIER CANADA_
_Used in the instruction of Canadian Troops._]
Drainage
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account