Experimental Researches in Electricity, Volume 1 — John Shaqi
Experimental Researches in Electricity, Volume 1Faraday, Michael
Science
Experimental Researches in Electricity, Volume 1
Faraday, Michael
Electricity; Electricity -- Early works to 1850
86. Conductors or electric collectors of copper and lead were constructed
so as to come in contact with the edge of the copper disc (85.), or with
other forms of plates hereafter to be described (101.). These conductors
were about four inches long, one third of an inch wide, and one fifth of an
inch thick; one end of each was slightly grooved, to allow of more exact
adaptation to the somewhat convex edge of the plates, and then amalgamated.
Copper wires, one sixteenth of an inch in thickness, attached, in the
ordinary manner, by convolutions to the other ends of these conductors,
passed away to the galvanometer.
87. The galvanometer was roughly made, yet sufficiently delicate in its
indications. The wire was of copper covered with silk, and made sixteen or
eighteen convolutions. Two sewing-needles were magnetized and fixed on to a
stem of dried grass parallel to each other, but in opposite directions, and
about half an inch apart; this system was suspended by a fibre of unspun
silk, so that the lower needle should be between the convolutions of the
multiplier, and the upper above them. The latter was by much the most
powerful magnet, and gave terrestrial direction to the whole; fig. 8.
represents the direction of the wire and of the needles when the instrument
was placed in the magnetic meridian: the ends of the wires are marked A and
B for convenient reference hereafter. The letters S and N designate the
south and north ends of the needle when affected merely by terrestrial
magnetism; the end N is therefore the marked pole (44.). The whole
instrument was protected by a glass jar, and stood, as to position and
distance relative to the large magnet, under the same circumstances as
before (45.).
88. All these arrangements being made, the copper disc was adjusted as in
fig. 7, the small magnetic poles being about half an inch apart, and the
edge of the plate inserted about half their width between them. One of the
galvanometer wires was passed twice or thrice loosely round the brass axis
of the plate, and the other attached to a conductor (86.), which itself was
retained by the hand in contact with the amalgamated edge of the disc at
the part immediately between the magnetic poles. Under these circumstances
all was quiescent, and the galvanometer exhibited no effect. But the
instant the plate moved, the galvanometer was influenced, and by revolving
the plate quickly the needle could be deflected 90 deg. or more.
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account