plug while inserting it and pulling it out, the likelihood of breaking
the internal connections and wearing out the wires will be reduced to a
minimum.
Disadvantages of the Monocord Switchboard.
1. It does not afford as quick connections as the by-cords switchboard
type.
2. It is not self-contained. A self-contained switchboard includes
operators, receiver and transmitter and ringing and night alarm
circuits.
3. The operator’s telephone is usually equipped with a hand set,
(receiver and transmitter) which leaves him with only one free hand for
making connections.
4. One switchboard is equipped with but one master, or operators cord,
this affords only one means of answering and calling.
Advantages of the Monocord Switchboard.
1. Small, compact, light weight.
2. Simple wiring.
3. Quickly installed.
4. Particularly suited for small central exchanges.
5. Units can be removed quickly, in case of trouble in interior
circuits. Any unit can be removed without disturbing other units.
Common Faults and Remedies of the Magneto Telephone.
The most common trouble in telephone instruments are due generally to
one of three causes. (1) Loose or dirty connections at the binding
posts of the instrument, at the binding posts of the batteries, or in
joints of the line wires, (2) exhausted, poor, or weak batteries, (3)
crossed, open, or defective wires. These troubles, of course, do not
include those arising from inferior or defective instruments. If the
connections are dirty, corroded or greasy, scrape the wires and clean
out the binding posts, then screw the wires firmly in place. If the
telephone does not then work properly, examine the batteries and see
whether they are run down or whether the zincs are eaten away. With
wet batteries, it may be possible that the water has evaporated; in
dry batteries, the zincs may be eaten through or the batteries may be
otherwise defective. The simplest way to test a battery is to try a new
battery, and see whether it will make the telephone work properly; if
it does, the trouble is with the old battery. If the trouble is present
after changing the battery, examine the line connections and the line
outside; if any loose connections are found, correct them at once. When
inspecting the line outside see that it does not touch anything except
the insulators, and that it is neither crossed nor broken. On grounded
lines—grounded lines are obsolete now in modern warfare on the account
of the many means of detecting and picking up messages now employed; in
fact the metallic circuit telephone lines are now used within a mile of
the front lines except for messages which would be of no value to the
enemy—examine the ground connections the first thing and see whether it
is in good condition, and if a plate is used see that it is in moist
ground. The frequent trouble with transmitters is the frying noise;
that is usually caused by induction or static electricity, and may also
be caused by loose connections.