Hand-book of Sanitary Information for Householders: Containing facts and suggestions about ventilation, drainage, care of contageous diseases, disinfection, food, and water. With appendices on disinfectants and plumbers' materials.Tracy, Roger Sherman
Science
Hand-book of Sanitary Information for Householders: Containing facts and suggestions about ventilation, drainage, care of contageous diseases, disinfection, food, and water. With appendices on disinfectants and plumbers' materials.
Tracy, Roger Sherman
Disinfection and disinfectants; Drinking water; Food adulteration and inspection; Hygiene; Sanitation, Household; Ventilation
16. No brick, sheet-metal, earthenware, or chimney-flue shall be used
as a sewer-ventilator, nor to ventilate any trap, drain, soil, or waste
pipe.
17. Every vertical soil-pipe and waste-pipe must be of iron, and, where
it receives the discharge of fixtures on two or more floors, it must
be extended at least two feet above the highest part of the roof or
coping, of undiminished size, with a return bend or cowl. It must not
open near a window, nor an air-shaft which ventilates livingrooms.
18. Soil, waste, and vent pipes, in an extension, must be extended
above the roof of the main building, when otherwise they would open
within twenty feet of the windows of the main house or the adjoining
house.
19. Horizontal soil and waste pipes are prohibited.
20. The minimum diameter of soil-pipe permitted is four inches. A
vertical waste-pipe, into which a line of kitchen-sinks discharge, must
be at least two inches in diameter, with one inch and a half branches.
21. Where lead pipe is used to connect fixtures with vertical soil or
waste pipes, or to connect traps with vertical vent-pipes, it must not
be lighter than D-pipe.
22. There shall be no traps on vertical soil-pipes or vertical
waste-pipes.
23. All iron pipes must be sound, free from holes, and of a uniform
thickness of not less than one eighth of an inch for a diameter of two,
three, or four inches, or five thirty-seconds of an inch for a diameter
of five or six inches; and, in case the building is over sixty-five
feet in height above the curb, the use of what is known as extra heavy
pipe, and corresponding fittings, are required, which weigh as follows:
2 inches, 5½ pounds per lineal foot.
3 ” 9½ ” ”
4 ” 13 ” ”
5 ” 17 ” ”
6 ” 20 ” ”
7 ” 27 ” ”
8 ” 33½ ” ”
10 ” 45 ” ”
12 ” 54 ” ”
24. Before they are connected they must be thoroughly coated inside
and outside with coal-tar pitch, applied hot, or some other equivalent
substance.
25. When required by an inspector from the Board of Health, the
plumbing must be tested with the peppermint or the water test, by the
plumber in the presence of the inspector, and all defective joints made
tight, and other openings made impermeable to gases. Defective pipe
discovered must be removed and replaced by sound pipe.
26. All joints in the iron drain-pipes, soil-pipes, and waste-pipes
must be so calked with oakum and lead, or with cement made of iron
filings and sal-ammoniac, as to make them impermeable to gas.
27. All connections of lead with iron pipes must be made with a brass
sleeve or ferrule, of the same size as the lead pipe, put in the hub
of the branch of the iron pipe, and calked in with lead. The lead pipe
must be attached to the ferrule by a wiped joint.
28. All connections of lead pipe should be by wiped joints.