The mercury arc is peculiar in that it acts as an electric valve
tending to let current flow through it only in one direction. Thus
on alternating current, the current impulses will readily go through
it in one direction, but the arc will go out in the other half cycle
unless means are taken to prevent this. This is accomplished by having
two terminals at one end of the tube, which are connected to choke
coils, which in turn are connected to a single coil (auto) transformer.
The alternating current supply mains are connected to wires tapping
different parts of the coil of the auto transformer. The center of
the coil of the auto transformer is connected through an induction
coil to the other end of the tube. By this means the alternating
current impulses are sent through the tube in one direction, one half
cycle from one of the pairs of terminals of the tube, the other half
cycle from the other terminal. Thus pulsating direct current, kept
constant by the induction coil, flows through the tube, the pulsations
overlapping each other by the magnetic action of the choke coils. This
alternating current lamp is started by the high voltage discharge
method. It has a 50-inch length of tube, consuming about 400 watts on
110 volts. Its efficiency is a little less than that of the direct
current lamp.
[Illustration: DIAGRAM OF COOPER-HEWITT LAMP FOR USE ON ALTERNATING
CURRENT.
The mercury arc is inherently for use on direct current, but by means
of reactance coils, it can be operated on alternating current.]
THE LUMINOUS OR MAGNETITE ARC LAMP
About 1901 Dr. Charles P. Steinmetz, Schenectady, N. Y., studied the
effect of metallic salts in the arc flame. Dr. Willis R. Whitney,
also of Schenectady, and director of the research laboratory of the
organization of which Dr. Steinmetz is the consulting engineer,
followed with some further work along this line. The results of this
work were incorporated in a commercial lamp called the magnetite arc
lamp, through the efforts of C. A. B. Halvorson, Jr., at Lynn, Mass.
The negative electrode consists of a pulverized mixture of magnetite
(a variety of iron ore) and other substances packed tightly in an iron
tube. The positive electrode is a piece of copper sheathed in iron to
prevent oxidization of the copper. The arc flame gives a brilliant
white light, and, similar to the mercury arc, is inherently limited to
direct current. It burns in the open air at about 75 volts. The lamp is
made for 4-ampere direct current series circuits and consumes about 310
watts and has an efficiency of about 11½ lumens per watt.
[Illustration: LUMINOUS OR MAGNETITE ARC LAMP, 1902.
This has a negative electrode containing magnetite which produces a
very luminous white flame in the arc stream.]