13. Rooms in which suction gas plant is installed must be of
such a height that all the plant and its connections can be
easily reached for cleaning, &c., and be capable of such free
ventilation as to render impossible an accumulation of gas.
14. These rooms must be separated from living rooms by a wall
without any openings in it. Emanations also must be prevented
as far as possible from entering into living or working rooms
situated over the gas engine.
15. Erection of apparatus for generating and purifying suction
gas in cellars shall only be allowed if specially effective
ventilation is provided by natural or mechanical means.
Other Regulations are those of the Prussian Ministerial Decree, dated
June 20, 1904, as to the arrangement and management of suction gas
premises.
ACETYLENE GAS INSTALLATIONS
(See also pp. 85-7)
The following regulations for the protection of workers in acetylene gas
installations are taken from the Prussian Ministerial Decree, dated 2
November, 1897:
1. Preparation and condensation of acetylene on the one hand,
and liquefaction on the other, must be carried on in separate
buildings.
2. If the pressure employed for condensation of the gas exceeds
eight atmospheres, this work must take place in a room set
apart for the purpose.
3. Rooms in which acetylene is prepared, condensed, or
liquefied shall not be used as, nor be in direct connection
with, living rooms. They must be well lighted and ventilated.
4. The carbide must be kept in closed watertight vessels, so
as to ensure perfect dryness and only such quantities shall
be taken out as are needed. The vessels must be kept in dry,
light, well-ventilated rooms; cellar rooms may not be used for
storage purposes.
5. Crushing of carbide must be done with the greatest possible
avoidance of dust. Workers are to be provided with respirators
and goggles.
6. Acetylene gasometers must be fitted up in the open air or in
a well-ventilated room, separated from the gas generator. Every
gas receiver must have a water gauge showing the pressure in
the receiver.
7. Between the gasometer and receiver a gas purifier must be
provided so as to remove impurities (phosphoretted hydrogen,
arseniuretted hydrogen, carbon bisulphide, ammonia, &c.).
8. Condensation of acetylene gas at a pressure exceeding ten
atmospheres shall only be done in combination with cooling.