"Lest We Forget": Chicago's Awful Theater HorrorEverett, Marshall
History
"Lest We Forget": Chicago's Awful Theater Horror
Everett, Marshall
Iroquois Theater, Chicago -- Fire, 1903; Theaters -- Fires and fire prevention
"Every theater in Chicago is virtually a death trap set for patrons even
under ordinary conditions. Barring fires and panics, the playhouses are
not amply provided with exits, and are unsafe on account of overcrowding.
Thereby each person attending a performance in any of Chicago's theaters
does so at a risk of his own life. This also applies to all halls that are
hurriedly arranged for public meetings and especially during the election
campaign work and convention gatherings.
"A theater may be absolutely fire-proof, but when the seating capacity of
the house has been overcrowded by reducing sizes of stairs, aisles and
exits the building is really worse than a non-fire-proof building, for in
the latter the smoke would have a chance to escape.
"The following suggestions will partially avert such a horror as has been
witnessed at the Iroquois, which was advertised as the safest fire-proof
theater in Chicago:
"All seats throughout the house should be placed far enough apart from
back to back so that an open passageway running from aisle to aisle shall
be large enough to allow a person to get out without disturbing all the
people seated in the section. In the Iroquois the seats in the gallery are
so closely spaced from back to back that one cannot sit in a comfortable
position at any time. All seats should be made of iron framework, with
seats fixed so that danger of catching clothing on upturned edges may be
averted, which in the present theater seats causes very much delay in a
rush. The upholstering should be done with asbestos wool and all covering
done with asbestos fire-resisting cloth.
"An aisle should be left between the orchestra and the front row of seats.
Main aisles should be made so that they connect with the aisle in front,
also the aisle in rear, without any obstructions, and an exit door placed
at end of each aisle leading directly to the vestibule. The present system
is one large door at the center so that people from the side aisles
collide with those from the center aisles and no one can get out. It is
also very important that the door opening, with doors open, is a trifle
larger than the aisle; all seats that face on aisles to be plain to
prevent clothing from catching on same.
"Carpets should be prohibited in all halls and aisles and replaced by
interlocking rubber tile or some similar covering to prevent slipping in a
rush.
"All steps should have safety treads, composed of steel and lead, in place
of slate or marble, which becomes slippery and dangerous. Stairs to be
straight without winds or turns and at every ten feet from the sidewalk
there should be a landing twice as long as the width of the stairs and
doors at the foot of the stairs should be a trifle larger than the stair
opening.
"All balconies and galleries above the first floor should have a metal
hand rail back of each row of seats securely fastened to the floor
construction.