"Doors should swing out; in addition to door handle threshold to have an
automatic opening device so as to throw doors open in case of fire or
accident. Also at each fire exit there should be in view of the audience a
box containing saw and tools and plainly marked for use in case of fire,
providing locks on doors fail to work. In addition an attendant should be
placed at each fire exit and remain there until the house is vacated
during every performance.
"Fire escapes should be made of regular stair pattern with treads eleven
inches and rises seven inches, and treads provided with steel and lead
composition covering and risers closed.
"Instead of sloping the ceiling toward the stage it should be made level
with a cone shape toward the center and there connect with a down draft
ventilator and an emergency damper controlled by a three-way switch from
stage, box office and each balcony, made large enough to form a smoke flue
in case of fire. Wires controlling this ventilator should run in conduit
fireproofed and in addition to switch an electric emergency switch
weighted with a fused link to make a contact when link breaks. Same to
apply to stage, halls and stairways, except that fireproof ducts will
connect halls and stairs with outer air. In addition to the ventilator
every part of the house should be equipped with a system of sprinklers
operated automatically by a gravity system. A large glass chandelier such
as used at the Iroquois should be prohibited.
"Emergency lights in case of fire and accidents during the performance to
light up the house should be placed on ceiling of main auditorium,
balconies, halls and stairs and built of fire-proof boxes with wired
plate-glass face. These lights should be operated on a separate system and
run in fireproof conduits, and controlled from the street front, also to
have a fusible weighted switch on stage.
"Fire doors should be constructed of steel with wired plate-glass panels
so that fire can be prevented from outside sources, but if in case of
accident the lock should fail to work from the inside, the glass panel can
be broken with tools that should be placed in reach and plainly marked.
"Calcium lights should be prohibited anywhere in the auditorium. The place
is generally on the gallery. In the Iroquois the scenic lights were placed
at the extreme top of the upper gallery, with a supporting framework that
rested on the aisle floor and obstructed aisle to audience.
"Counter-weights of curtain should be made in sections with fusible link
connections so that in case of fire curtain will drop of its own weight.
"Curtain should be constructed of steel framework and made rigid and run
in steel guides of sufficient size to allow for expansion in case of fire.
Stage floor should be four inches thick, solid, laid on concrete bed.