Manual for submarine miningUnited States. War Department
History
Manual for submarine mining
United States. War Department
Submarine mines -- Handbooks, manuals, etc.
The universal shunt is always employed with the galvanometer and is
used both to vary the current through the latter and to protect it from
a violent throw at the instant of making or breaking the circuit at the
testing key. This last is accomplished by having the shunt on zero at
such times.
The galvanometer being a very sensitive instrument must be solidly
supported so as to be free from jars or vibrations.
The special testing key, shown diagrammatically in the figure, has its
binding posts plainly marked. It is a double-throw key and has two
positions upon each side. When completely closed to the right, the
cable is charged through the galvanometer from the positive pole; when
to the left, from the negative pole of the battery. In each case the
deflection of the galvanometer is in the same direction. When partly
closed on either side, the cable is discharged to earth through the
galvanometer. (Note: It will be observed that the connections are such
that the galvanometer is always connected to the cable core and never
to the ground. With this connection, _so long as the lead PX is free
from leaks or grounds_, the galvanometer measures only the current
actually passing through the core and not that leaking through any
imperfect insulation in the battery and leads.)
Cable testing is a very simple operation, but extreme care is necessary
in all operations.
[Illustration: FIG. 16.—CABLE TESTING.]
The following is a detailed description:
=I. Preparing the cable for testing.=—1. Closely examine each conductor
end. Look particularly for unusually hard or brittle insulation and for
torn, pinched, or punctured insulation, especially near the ends of the
armor wires. If any of the ends are not in perfect condition, cut off
enough cable to secure good ends. (_Caution._—Do not cut off more than
enough to secure good ends, for after three or four tests it may be
necessary to unreel the whole cable to secure enough of the inner end
above water.)
2. Verify the tagging. Remember that the “shore end” is the end from
the outer coils on the reel and is numbered clockwise. The other end is
numbered contraclockwise.
3. The “ground” should be made by taking several turns of bare copper
wire around the armor of the cable to be tested and soldering them in
position. One such ground in each tank is sufficient. Whenever “ground”
or “earth” is subsequently spoken of, this ground in the tank is meant,
and not a connection to ground at some point outside the tank.
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Elsewhere in the archive
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account