4. _Insulation of leads._—Turn the shunt to 0. Open the battery switch.
Connect the earth leads BY and EY to their proper posts. Connect the
cable lead, PX, to “cable” post. See that the cable tank ends of the
lead PX is disconnected at X and suspended in the air. Close the
battery switch. Close the key and turn the shunt to the unity post.
Deflections should be as small as possible and in any case _must be
steady and uniform for several trials_. Turn the shunt to 0. Reverse
the key, stopping at the discharge position. Turn the shunt to the
unity post and wait until the galvanometer rests at 0, indicating that
the leads are discharged. Turn the shunt to 0. Close the key all the
way down. Turn the shunt to the unity post. The deflection should not
differ materially from that noted above. If there is a deflection, the
trouble is in the lead PX or its connections. Go over these, carefully
examining for dust and moisture and noting particularly the proximity
of all wires of opposite potential which cross or lie near each other.
If there is a small deflection which can not be removed, a correction
must be applied subsequently to the deflection obtained in the test for
the insulation resistance of the conductor.
Using proper care, there are very few days when perfect insulation
of the instruments can not be secured. The lead leakage with
well-insulated wire put up properly will be noticed rarely.
5. _Use of Price guard-wire._—As an additional precaution against
surface leakage across the insulation at the ends of the conductor
it will sometimes be advisable to install an additional lead (not
necessarily as carefully insulated as PX) running from the testing
switch to the cable under test. This lead should be connected in at the
testing switch to the post carrying the lower blade between “D” and “C”
(fig. 16); the tank end should be bare of insulation for a sufficient
distance to enable the bare wire to be wrapped firmly, without
pinching, around the insulation at each end of the particular conductor
under test, just below the tapered portion.
The potential difference between the cable core and this guard-wire
is thus made practically nil, so that any leakage will be from the
guard-wire to the tank, consequently this leakage will not be measured
by the galvanometer.
=IV. Take the galvanometer constant as follows=: Open the battery
switch.