Manual for submarine mining
United States. War Department
Submarine mines -- Handbooks, manuals, etc.
4. The left-hand switch, a S. P. D. T. switch, is the “testing switch.”
It is used to test the automatic switch, which should open when the
testing switch is thrown down. The bell switch should be opened before
throwing down testing switch. When the testing switch is in this
position, the circuit being broken at its upper contact, the mine is
cut out, and in place of the mine there is thrown in the red lamp of
the signal block. The resistance of this red lamp is greater than that
of the mine circuit when the mine is struck, so that if the automatic
switch works for the current through the red lamp it will certainly
work for that through the circuit closer when the mine is struck.
The circuit when the testing switch, T, is down and _before_ the
automatic switch drops is: From negative D. C. bus on power panel, to
switch 3 closed up, to “operating board” terminal, to D. C. lead, to
D. C. post on signal block, through green lamp, to D. C. jaw, to D.
C. bus on operating board, through power switch, through solenoid to
middle of testing switch T, to lower point of same, to operating board
lamp bus L, through red lamp to “earth” post, to earth lead, to D. C.
“earth” terminal on power panel, to switch 3, and to positive D. C.
bus on power panel. The circuit, when testing switch, T, is down, and
_after_ the automatic switch has dropped, is the same as the above up
to the power switch, then from the power switch through the insulated
pin in the lower part of the automatic switch, to the lower jaw of the
testing switch, and then the same as the circuit above.
A diagram similar to the wiring diagram, figure 18, at the end of the
book should be made of the power panel and of one of the operating
boards of each casemate and posted in a conspicuous place in the
casemate. Any changes made in the wiring of either of these boards
should be made immediately on this diagram.
=Submarine mine cable, 19-conductor.=—This is an armored cable about
1 inch in diameter and contains 19 insulated single conductors of No.
16 American wire gauge wire (51 mils in dia.). The conductors are
arranged in two concentric layers around a single central conductor,
the inner layer containing 6, the outer 12. One conductor in each layer
is distinguished from the rest by some characteristic mark, as a spiral
white thread, a wrapping of tape, or other easily detected mark. The
marked conductor in the outer layer is No. 1, that in the inner layer
No. 13, and the central conductor is No. 19. The other conductors are
numbered at the shore end of the cable in a clockwise direction; at the
distant end in a contraclockwise direction.
=Submarine mine cable, 7-conductor.=—In many cases the 7-conductor
cable now on hand can be used to advantage for mine work, particularly
in planting groups which do not require great lengths of multiple
cable. In all such cases the old grand junction boxes are to be used as
distribution boxes, thus providing for separate groups of 7 mines.