Inventions; Science; Technology -- Social aspects; Technology and civilization
The steel columns reach from the foundation to the top, riveted together
by plates and may be extended to an indefinite height. In fact there
is no engineering limit to the height.
The outside walls of the sky-scraper vary in thickness with the height
of the building and also vary in accordance with the particular kind
of construction, whether cage or skeleton. If of the cage variety, the
walls, as has been said, act as curtains and consequently they are
thinner than in the skeleton type of construction. In the latter case
the walls have to resist the wind pressure unsupported by the steel
frame and therefore they must be of a sufficient width. Brick and
terra-cotta blocks are used for construction generally.
Terra-cotta blocks are also much used in the flooring, and for this
purpose have several advantages over other materials; they are
absolutely fire-proof, they weigh less per cubic foot than any other
kind of fire-proof flooring and they are almost sound-proof. They do
equally well for flat and arched floors.
It is of the utmost importance that the sky-scraper be absolutely
fire-proof from bottom to top. These great buzzing hives of industry
house at one time several thousand human beings and a panic would
entail a fearful calamity, and, moreover, their height places the upper
stories beyond reach of a water-tower and the pumping engines of the
street.
The sky-scrapers of to-day are as fireproof as human ingenuity and
skill can make them, and this is saying much; in fact, it means that
they cannot burn. Of course fires can break out in rooms and apartments
in the manufacturing of chemicals or testing experiments, etc., but
these are easily confined to narrow limits and readily extinguished
with the apparatus at hand. Steel columns will not burn, but if exposed
to heat of sufficient degree they will warp and bend and probably
collapse, therefore they should be protected by heat resisting agents.
Nothing can be better than terra-cotta and concrete for this purpose.
When terra-cotta blocks are used they should be at least 2 inches thick
with an air space running through them. Columns are also fire-proofed
by wrapping expanded metal or other metal lathing around them and
plastering.
Then a furring system is put on and another layer of metal, lathing
and plastering. This if well done is probably safer than the layer of
hollow tile.
The floor beams should be entirely covered with terra-cotta blocks or
concrete, so that no part of them is left exposed. As most office
trimmings are of wood care should be taken that all electric wires are
well insulated. Faulty installation of dynamos, motors and other
apparatus is frequently the cause of office fires.