As the temperature goes lower, less and less moisture is required to
saturate the air. If saturated air at 0°F., which contains 0.48 grain
of water, is raised to 70°F.--where 8 grains of water is required for
saturation--the percentage of saturation would be 0.48/8 or 6 per cent.
=The Hygrometer.=--The instrument most commonly employed for
determining atmospheric humidity is the hygrometer. This appliance
is composed of two thermometers mounted in a frame with a vessel for
holding water. One of the thermometers is intended to register the
temperature of the air and is called the dry-bulb thermometer. The
bulb of the other--the wet-bulb thermometer--is covered with a piece
of cloth or other porous material which is kept saturated with water,
absorbed from the water holder. The dryness of the air is indicated
in the wet-bulb thermometer by the decline of temperature due to
evaporation.
The rate of evaporation from the wet-bulb covering will vary with
the humidity and if the air is very dry the wet-bulb thermometer
will register a temperature several degrees below that of the other
thermometer. If the air is saturated with moisture, no evaporation will
take place and the thermometers will read alike. The relative humidity
of the air as indicated by the readings of the thermometers is taken
directly from a humidity table. The table is made to suit any condition
of atmospheric humidity and the determinations require no calculation.
[Illustration: FIG. 157.--Hygrometer of U. S. Weather Bureau type; for
determining atmospheric humidity.]
Fig. 157 shows the U. S. Weather Bureau pattern hygrometer such as is
used at the weather stations. The wet-bulb thermometer has a muslin or
knitted silk covering which dips into a metal water cup as shown in the
figure. It is important that the covering of the wet bulb be kept in
good condition. The evaporation of the water from the covering leaves
in the meshes particles of solid matter that were held in solution in
the water. The accumulation of the solids ultimately prevent the water
from thoroughly wetting the wick.
An observation consists in reading the two thermometers and from the
difference between the wet-bulb reading and that of the dry-bulb, the
relative humidity is taken directly from the table. To illustrate,
suppose that the dry-bulb thermometer reads 60° and that the wet-bulb
reads 56°. The difference between the two readings is 4°. In the
table of relative humidity on page 202, 60° is found in the column
headed, Air temp. _t_, and opposite that number in the column headed
4 is 78, which indicates that under the observed conditions the air
is 78 per cent. saturated with moisture. This table is suited for
air temperatures from 35°F. to 80°F. and depressions of the wet-bulb
thermometer from 1°F. to 20°F. The table, therefore, has a range of
variations which will admit humidity determinations for all ordinary
conditions.