Sec. 948. [=Voltage at mines hereafter electrically equipped.=] The
owner, lessee or agent of a mine at which electricity with a
pressure or potential of more than three hundred and twenty-five
volts, or alternating current, is used, shall in addition to the
provisions of the preceding section, observe the following:
[=Limit to voltage in or about working places.=] At each mine
equipped with electric power after the passage and approval of this
act, the current used to operate gathering locomotives, mining
machines, shearing machines, drills and other machinery, used in or
about the working places of the mine, shall not exceed in pressure
or potential, three hundred and twenty-five volts, direct current,
as shown at the nearest switchboard, and the wires conducting the
power from the nearest switchboard shall not carry a higher pressure
or potential.
[=Relating to alternating current.=] At each mine equipped with
electric power alternating current may be used to convert
alternating current to direct current, and to operate motors
permanently installed above ground and in underground substations,
or buildings especially prepared for them, in a manner subject to
the approval of the chief and district mine inspectors, but no wires
carrying alternating current shall be used underground except same
be carried in an entry or passageway where persons and animals are
not permitted to travel.
[=Relating to higher voltage mines hereafter equipped.=] At each
mine equipped with electric power after the passage and approval of
this act, when the current used to operate haulage locomotives,
pumps and other machinery not located in or about the working places
of the mine, is of a pressure or potential in excess of three
hundred and twenty-five volts, direct current, the entry or passage
way where such wires are carried shall not be designated or
permitted to be used as the principal traveling way, and when
designated or used as the escapement way, the wires shall be
protected so that persons required to travel near same in
emergencies will not inadvertently come in contact therewith. No
pressure in excess of six hundred and fifty volts at the switchboard
shall be used underground.
[=Relating to higher voltage, mines heretofore equipped.=] At each
mine equipped with electric power prior to the passage and approval
of this act, where the pressure or potential is in excess of three
hundred and twenty-five volts, direct current, or where alternating
current is used, and the conditions surrounding the use of same are
such, in the opinion of the chief inspector of mines, that the
provisions of the preceding section do not provide the required
protection from shock to persons employed therein, such additional
safeguards shall be employed as may be required by the chief
inspector of mines, and the district inspector of mines, jointly.
(See. 911, 947; Penalty, Sec. 976.)