The present appearance of the eye-end is shown in the illustration. The
plate-holder is there shown, however, on one side of the tube, and its
longer side is parallel to the axis of the telescope. This is not a good
position for the eye-end, except for short exposures. In practice, the
eye-end is always placed on the north or south side of the tube, according
as the object photographed is north or south of the zenith. The right
ascension slide is then always at right angles to the telescope axis, and
the eye-end can not get into an inaccessible position during a long
exposure.
As the original wooden plate-holders were warped, and could not be
depended upon to remain in the same position for several hours at a time,
they were replaced by new ones of metal, and clamping screws were added,
to hold them firmly in place. The heads of these screws are shown in the
plate, between the springs which press the plate-holder against its bed.
To illuminate the cross-wires of the guiding eyepiece, a small electric
lamp is used, the current for which is brought down from the storage
battery at the main Observatory. The coarse wires have been replaced by
spider's webs,[9] and reflectors have been introduced, to illuminate the
declination thread. A collimating lens, placed at its principal focal
distance from the incandescent filament of the lamp, makes the
illumination of the wires nearly independent of their position on the
slide, and a piece of red glass, close to the lens, effectually removes
all danger of fogging the plate. The light is varied to suit the
requirements of observation by rotating the reflector which throws the
light in the direction of the eyepiece.
[Illustration: DOUBLE-SLIDE PLATE-HOLDER OF THE CROSSLEY REFLECTOR.]
In long exposures it is important for the observer to know at any moment
the position of the plate with reference to its central or zero position.
For this purpose scales with indexes are attached to both slides; but as
they can not be seen in the dark, and, even if illuminated with red light,
could not be read without removing the eye from the guiding eyepiece, I
have added two short pins, one of which is attached to the lower side of
the right ascension slide, and the other to its guide, so that the points
coincide when the scale reads zero. These pins can be felt by the fingers,
and with a little practice the observer can tell very closely how far the
plate is from its central position. It would not be a very difficult
matter to improve on this contrivance, say by placing an illuminated
scale, capable of independent adjustment, in the field of the eyepiece,
but the pins answer every purpose. The declination slide is changed so
little that no means for indicating its position are necessary.
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account