Brain tumors tend to concentrate certain ions (charged atoms or
molecules). When these ions are gamma-ray emitters, it is possible to
take advantage of the penetrating power of their gamma rays to locate
the tumor with a scanning device located outside the skull.
Arsenic-74 and copper-64 are isotopes emitting _positrons_,[8] which
have one peculiar property. Immediately after a positron is emitted from
a nucleus it decays, producing two gamma rays that travel in exactly
opposite directions. The scanning device has two detectors called
scintillation counters, one mounted on each side of the patient’s head.
The electrical circuitry in the scanner is such that only those gamma
rays are counted that impinge simultaneously on both counters. This
procedure eliminates most of the “noise”, or scattered and background
radiation.
Chromium-51
Because chromium, in the molecule sodium chromate, attaches itself to
red blood cells, it is useful in several kinds of tests. The procedures
are slightly complicated, but yield useful information. In one, a sample
of the patient’s blood is withdrawn, stabilized with heparin (to prevent
clotting) and incubated with a tracer of radioactive sodium chromate.
Excess chromate that is not taken up by the cells is reduced and washed
away. Then the radioactivity of the cells is measured, just before
injection into the patient. After a suitable time to permit thorough
mixing of the added material throughout the blood stream, a new blood
sample is taken and its radioactivity is measured. The total volume of
red blood cells then can be calculated by dividing the total
radioactivity of the injected sample by the activity per milliliter of
the second sample.
[Illustration: _Spleen scans made with red blood cells, which had been
altered by heat treatment and tagged with chromium-51. Such damaged
cells are selectively removed by the spleen. A is a normal spleen. B
shows an abscess in the spleen. Note dark ring of radioactivity
surrounding the lighter area of decreased activity at the central
portion of spleen._]
In certain types of anemia the patient’s red blood cells die before
completing the usual red-cell lifetime of about 120 days. To diagnose
this, red cells are tagged with chromium-51 (⁵¹Cr) in the manner just
described. Then some of them are injected back into the patient and an
identical sample is injected into a compatible normal individual. If the
tracer shows that the cells’ survival time is too short in both
recipients to the same degree, the conclusion is that the red cells
themselves must be abnormal. On the other hand, if the cell-survival
time is normal in the normal individual and too short in the patient,
the diagnosis is that the patient’s blood contains some substance that
destroys the red cells.