_Class A._--All buildings, outhouses, and other superstructures of
class A shall have floors made of rat-proof material or of concrete,
which concrete shall be not less than 3 inches thick, and overlaid
with a top dressing of cement, mosaic, tiling, or other impermeable
material laid in cement mortar, and such floor shall rest without
any intervening space between upon the ground or upon filling of
clean earth, sand, cinders, broken stone or brick, gravel, or similar
material, which filling shall be free from animal or vegetable
substances; said floor shall extend and be hermetically sealed to
walls surrounding said floor, which walls shall be made of rat-proof
material or of concrete, stone, or brick laid in cement or mortar,
and each wall shall be not less than 6 inches thick and shall extend
into and below the surface of the surrounding ground at least 2 feet
and shall extend not less than 1 foot above the surface of said
floor; provided that wooden removable gratings may be laid on such
concrete floors in such parts of such buildings, superstructures,
and outhouses as are used exclusively as sales departments, provided
that wooden flooring may be laid over the concrete wherever the
intervening space between such flooring and the concrete shall not
exceed one-half inch; provided further that any sleepers that are
sunk into the concrete shall be creosoted.
_Class B._--All accidental and unnecessary spaces and holes,
ventilators, and other openings other than doors and windows in every
building, outhouse or other superstructure in the city of --------,
shall be closed with cement, mortar, or other material impervious to
rats or screened with wire having not more than one-half inch mesh,
as the case may require, and all wall spaces shall be closed with
cement, mortar, or other material impervious to rats, which closure
shall extend the full thickness of the wall and shall extend upward
at least twelve inches above the floor level, and the whole in such
manner as to prevent the ingress or egress of rats; or the ingress
or egress of rats from such double wall or space may be prevented by
protecting the junction of said wall with the floor or other wall
with metal flashing of galvanized iron of 28 or 30 gauge, provided
that where such double wall is open beneath or is in communication
with foundations of the house that said opening shall be effectively
closed or said junction with foundations flashed with metal as
provided above: _Provided_, That in all buildings, outhouses, and
other superstructures of class A and in all stables where there are
any spaces in walls between the wall proper and the covering on
same, or in ceilings between the ceiling and floor, or other ceiling
covering above, said spaces shall be eliminated by the removal of
said covering, or so closed with cement, mortar or other material