The Ski-optometer is “an automatic trial-case” in the broadest sense
of the term, wholly superseding the conventional trial-case. It should
therefore be employed throughout an entire examination, wherever
trial-case lenses were formerly used. To fully realize its labor saving
value in obtaining accurate examination results, it is only necessary
to recall the tedious method of individually handling and transferring
each lens from the trial-case to the trial-frame, watching the stamped
number on each lens handle, wiping each lens and in the case of
cylindrical lenses setting each one at a designated axis—all being
needless steps where the Ski-optometer is employed.
THE USE OF THE SKI-OPTOMETER IN SKIOSCOPY
In skioscopy, the Ski-optometer offers the refractionist assistance of
the most valuable character.
For example, assuming that extreme motion in the opposite direction
with plane or concave mirror is obtained with a +1.25D. spherical
lens before the patient’s eye; by quickly turning the Ski-optometer’s
single reel until the two white zeros again appear, +2.50D is secured,
as explained in the previous chapter. If this continues to give too
much “against motion,” the lens power should be quickly increased to
+3.75 or +5.00D if necessary (Fig. 4). Should the latter reveal a
shadow in the reversed direction, the refractionist is assured that it
is the weakest lens that will cause its neutralization. Practically
but few lenses have been used to obtain the final result proving
the instrument’s importance and time-saving value in skioscopy, and
demonstrating the simplicity with which tedious transference of
trial-case lenses is avoided.
Furthermore, it should be noted that where the Ski-optometer is used
in skioscopy, it is not necessary to remove the retinoscope from the
eye or to constantly locate a new reflex with each lens change. This
permits a direct comparison of the final lens and eliminates the usual
difficulty in mastering skioscopy. The chief cause of this difficulty
is due to the fact that the transferring of the trial-case lenses makes
it practically impossible for the student to determine whether the
previous lens caused more “with” or “against” motion.
[Illustration: Fig. 9—The Woolf ophthalmic bracket. A convenient and
portable accessory in skioscopy and muscle testing; can be used with or
without Greek cross.]
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account