The present volume, dealing with the instrument’s distinctive operative
features, has been prepared not only for Ski-optometer users, but also
for those interested in the simplification of refraction and muscular
imbalance.
The author is indebted for invaluable counsel, to
Louis J. Ameno, M.D., New York.
E. LeRoy Ryer, O.D., New York.
Jos. D. Heitger, M.D., Louisville, Ky.
W. B. Needles, N.D., Kansas City, Mo.
INTRODUCTORY
While in a measure the conventional trial-case still serves its
purpose, so much of the refractionist’s time is consumed through the
mechanical process of individually transferring the trial-case spheres
and cylinder lenses, that far too little thought is given to _muscular
imbalance_, notwithstanding its _importance_ in all refraction cases.
Dr. Samuel Theibold, of Johns Hopkins University, in a recent address
before the American Medical Association, stated that the average
refractionist was inclined to devote an excess of time to general
refraction, completely overlooking the important test and correction of
muscular imbalance. If the latter is to be at all considered, general
refraction must be simplified—without impairing its accuracy—a result
that is greatly facilitated through the use of the Ski-optometer.
One must admit that tediously selecting the required trial-case
lens—whether sphere, cylinder or prism—watching the stamped number on
the handle—continual wiping and inserting each individual lens in a
trial-frame is a time-consuming practise. This is readily overcome,
however, through the employment of the Ski-optometer.
In a word, the Ski-optometer is practically an automatic trial-case,
bearing the same relation to the refracting room as the accepted labor
and time-saving devices of the day bear to the commercial world.
The present volume has accordingly been published, not alone in the
interest of those possessing a Ski-optometer, but also for those
interested in attaining _the highest point of efficiency_ in the work
of refraction and muscular imbalance.
[Illustration:
_Ski-optometer Lens Battery (almost actual size) showing how sphere and
cylinder lenses are procured._
_After obtaining FINAL results, your prescription is automatically
registered, ALL READY for you to transcribe._
Fig. 1—The three time-saving moves necessary in the operation of the
Ski-optometer.]
CHAPTER I
SKI-OPTOMETER CONSTRUCTION
A far better understanding of the instrument will be secured if the
refractionist possessing a Ski-optometer will place it before him,
working out each operation and experiment step by step in its proper
routine.
The three moves as outlined in Fig. 1 should first be thoughtfully
studied and the method of obtaining the spheres and cylinders carefully
observed.
[Illustration: Fig. 2—To Obtain Plano.]
1—Set spherical indicator at “000” as illustrated above.
2—Set cylinder indicator to “0”.
3—Set pointer of supplementary disk at “open”.