3. (1) If a building is situated at the side of a road no portion of the
building shall be higher than the distance from its base to the opposite
side of the street.
_Explanation._—If a building be placed at the edge of the road its
height must not exceed the width of the street; but if the building or
one or more of its stories be set back, the height of the building may
be increased as much as the basement of the increased portion is distant
from the adjoining edge of the road.
(2) In the case of any building which is re-erected in a road in
existence at the time when these rules come in force which is less than
25 feet wide but more than 20 feet, the proportion of height to width
may be as five to four up to a limit of 25 feet.
(3) Notwithstanding anything contained in sub-rule (1) or sub-rule (2)
the Chairman may give permission for building houses in the cases of
roads or lanes of less than 20 feet wide, after personal inspection in
each case.
(4) If a building is situated on a corner plot, the height of the
building shall be regulated by the wider of the intersecting streets.
[Sidenote: Level of floor.]
4. The floor or lowest floor of every building erected or re-erected
from the ground-level must be constructed at such level as will admit
of—
(_a_) The construction of a drain sufficient for the effectual
drainage of the building, and placed at such level as will admit
of the drainage being led into some Municipal drain at the time
existing or projected.
(_b_) The provision of the requisite communication with some drain
into which the drainage may lawfully be discharged, at a point in
the upper half of such drain, or with some other outfall into
which the drainage may lawfully be discharged.
[Sidenote: Building over Municipal drain.]
5. No foundation of any building shall be placed over any Municipal
drain, nor shall any superstructure whatever, whether verandah, balcony,
eave, or any other portion of the building, project beyond a vertical
line drawn through the centre of the drain, and if there be no drain,
not beyond 1 foot 6 inches from the edge of the road. But no material or
structure of any kind at or below the level of 6 feet from the ground,
with the exception of entrance culverts, allowed under Rule 7, shall
project over any part of a drain.
[Sidenote: Entrance culverts.]
6. The applications which are filed for entrance culverts must contain
the following particulars:—
(1) Length.
(2) Breadth beyond drain.
(3) Ventage allowed.
(_a_) Ordinarily the following dimensions will be allowed for foot
traffic:—
(1) two feet.
(2) ten inches.
(3) same size as area of drain up to a maximum of three square feet.
The number of entrance culverts in any building shall not exceed the
number of separate shops or dwelling-houses. The intervening space
between culverts over a drain shall not be covered over by planks, stone
slabs or any other substance.