When the north end of the needle and its index zero are north, the
needle rests at its index zero, but the slightest external influence,
such as a piece of iron 1 mm. in diameter 10 cm. distant, deflects the
needle to the right or left according to the polarity of its magnetism,
and with a force proportional to its power. If we place on the opposite
side of the needle at the same distance a wire possessing similar
polarity and force, the two are equal, and the needle returns to zero;
and if we know the magnetic value required to produce a balance, we know
the value of both. In order to balance any wire or piece of iron placed
in a position east and west, a magnetic compensator is used, consisting
of a powerful bar magnet free to revolve upon a central pivot placed
at a distance of 30 or more cm., so as to be able to obtain delicate
observations. This turns upon an index, the degrees of which are
marked for equal degrees of magnetic action upon the needle. A coil of
insulated wire, through which a feeble electric current is passing,
magnetizes the piece of iron under observation, but, as the coil itself
would act upon the needle, this is balanced by an equal and opposing
coil on the opposite side, and we are thus enabled to observe the
magnetism due to the iron alone. A reversing key, resistance coils, and
a Daniell cell are required."
The general design of the instrument, as shown in a somewhat crude form
when first exhibited, is given in the figure, where A is the magnetizing
coil within which the sample of iron or steel wire to be tested is
placed, B the suspended needle, C the compensating coil, and M the
magnet used as a compensator, having a scale beneath it divided into
quarter degrees.
The idea of employing a magnet as compensator in a magnetic balance is
not new, this disposition having been used by Prof. Von Feilitzsch in
1856 in his researches on the magnetizing influence of the current. In
Von Feilitzsch's balance, however, the compensating magnet was placed
end on to the needle, and its directive action was diminished at will,
not by turning it round on its center, but by shifting it to a greater
distance along a linear scale below it. The form now given by Hughes to
the balance is one of so great compactness and convenience that it
will probably prove a most acceptable addition to the resources of the
physical laboratory.--_Nature_.
* * * * *
HOW TO HARDEN CAST IRON.
Cast iron may be hardened as follows: Heat the iron to a cherry red,
then sprinkle on it cyanide of potassium and heat to a little above red,
then dip. The end of a rod that had been treated in this way could not
be cut with a file. Upon breaking off a piece about one-half an inch
long, it was found that the hardening had penetrated to the interior,
upon which the file made no more impression than upon the surface. The
same salt may be used to caseharden wrought iron.
* * * * *