The distribution of the heated air in the kiln is rarely as uniform as
is supposed, the temperature of the malt on drying floor being very
different at different parts. In illustration of this, the following may
be taken from a statement by Mr. Stopes of the results of an examination
of the temperatures at different parts of a drying floor in a kiln in
Norfolk: "A malting steeping 105 qr. every four days has a kiln 75
feet by 36 feet; an average drying area of under 26 feet per qr. The
consequent depth of green malt when loaded is over 10 inches. The total
area of air inlets is less than 27 feet super. The air outlet exceeds
117 feet, a ratio of 13 to 3. The capacity of head room equals 44,550
feet cube. The area of each tile is 144 inches, with 546 holes, giving
an effective air area of some 32 inches. The ratio of non-effective
metallic surface to air space is thus 9 to 2." The Casella anemometer
gave no indications at several points, and fluctuating up and down
draughts were observable at many others, especially at two corners and
along the center. "The strongest upward draught pulsated with the gusts
of wind and ranged from 30 feet to 54 feet per minute, a down draught of
equal intensity occurring at intervals at the same spot, notwithstanding
the fact that the air was rushing in at the inlets below the floor at
the high velocity of 785 feet per minute. The temperatures of the drying
malt and superimposed air consequent upon the conditions thus indicated
were naturally as follows: At B, the place supposed to be hottest: Heat
of malt touching tiles, 216 deg.; heat of malt 1 inch above tiles, 167
deg.; heat of malt 3 inches above tiles 154 deg.; heat of malt 4 inches
above tiles, 152 deg.; heat of malt 5 inches above tiles, 142 deg.; heat
of malt on surface, 112 deg. At A, the place supposed to be coldest:
Heat of malt next tiles, 174 deg.; heat of malt 2 inches above tiles,
143 deg.; heat of malt 4 inches above tiles, 135 deg.; heat of malt on
surface, 104 deg.; the heat of the air 3 feet above tiles, 84 deg.; the
heat of the air 5 feet above tiles, 82 deg. Fig. 9 shows the temperature
at twenty-six points close to the tiles, taken with twelve registered
and accurate thermometers in the space of fifteen minutes." These and
other similar tests have led to the conclusion that the best malt drying
cannot be done on a single floor.
Fig. 10 is a similar diagram showing the temperatures on a drying floor
of kiln at Poole, Dorset, altered to Stopes' system of drying. The
temperature at different depths of the drying grain was as follows: Malt
at surface of tiles, 142 deg.; malt at 1 inch above tiles, 142 deg.;
malt at 2 inches above tiles, 142 deg.; malt at 4 inches above tiles,
141 deg.; malt on surface, 140 deg.