Before the introduction of automatic sprinklers there was not, I believe,
a single instance of a fire entering the lower portion of a belt tower
during working hours without accomplishing the destruction of the mill.
Since the equipment of such places with automatic sprinklers, there have
been several fires of this nature extinguished with nearly nominal damage.
That is to say, the hazard of fire starting in such places is beyond the
capacity of any apparatus other than automatic sprinklers to cope with it.
It would be impossible to arrange the distribution of power in many mills
to conform to conditions of safety without reorganizing the whole plant,
which would, of course, be impracticable. But in many instances
modifications can be introduced which will diminish the hazard to a great
degree. When the pulleys and belting are covered with sheathing in each
room, the continuity of these flues can be broken by removing this
sheathing down to the height of four or five feet above the floor, so that
the covering will merely constitute a physical protection to any one
approaching the belting.
The best method of arranging the belt tower has been in the case of a mill
at Fall River, which was erected upon the ruins of a building destroyed by
a fire originating in the belt tower. The machinery is driven by a steam
engine situated in an ell projecting from one side at about the middle of
the mill; and the main belt communicates to pulleys in a stone masonry
tower located directly inside the walls of the main mill; and thence,
from pulley to pulley, the power is communicated to each floor by shafting
passing through holes left in the tower, and in no instances by means of
belts.
There is a separate stairway inside of the tower for lubricating the
journals, etc., and the top of the tower is covered with skylights
protected underneath by a wire netting. In case of a fire in the belt
tower, the heat will readily break the glass at the top, and the fire will
tend to go up and out of the tower rather than through the mill.
MILL FLOORS.
The questions involved in designing the floors of a mill are of great
importance, contributing in no small measure to elements concerned in the
successful operation of the mill, and to a greater extent to its standing
as a fire risk, and therefore affecting the constant expense of insurance.
In the case of a building designed merely for sustaining of loads, as in a
storehouse, a floor would naturally be designed on the basis of
considering the breaking strength of the timber. But in the case of a
mill, the limitation is the amount of flexure allowable under the
circumstances; and therefore the floors of the building are made more
nearly rigid than would be required merely from the consideration of the
ultimate strength of the structure.