The tar paper industry has, within the last forty years, assumed great
dimensions, and the preferences for this roofing are gaining ground
daily. In view of the small weight of the covering material, the wood
construction of the roof can be much lighter, and the building is
therefore less strained by the weight of the roof than one with the
other kind, so that the outer walls need not be as heavy. Considering
the price, the paper roof is not only cheaper than other fireproof
roofs, but its light weight makes it possible for the whole building
to be constructed lighter and cheaper. The durability of the tar paper
roof is satisfactory, if carefully made of good material; the double
tar paper roof, the gravel double roof, and the wood cement roof are
distinguished by their great durability.
These roofs may be used for all kinds of buildings, and not only are
factories, storehouses, and country buildings covered with it, but
also many dwellings. The most stylish residences and villas are at
present being inclosed with the more durable kinds; the double roof,
the gravel double roof, and the wood cement roof. For factory
buildings, which are constantly shaken by the vibrations of the
machinery, the tar paper roof is preferable to any other.
In order to ascertain to what degree tar paper roofs would resist
fire, experiments were instituted at the instigation of some of the
larger manufacturers of roofing paper, in the presence of experts,
architects, and others, embracing the most severe tests, and it was
fully proved that the tar paper roof is as fireproof as any other.
These experiments were made in two different ways; first, the
readiness of ignition of the tar paper roof by a spark or flame from
the outside was considered, and, second, it was tested in how far it
would resist a fire in the interior of the building. In the former
case, it was ascertained that a bright, intense fire could be kept
burning upon the roof for some time, without igniting the woodwork of
the roof, but heat from above caused some of the more volatile
constituents of the tar to be expelled, whereby small flames appeared
upon the surface within the limits of the fire; the roofing paper was
not completely destroyed. There always remained a cohesive substance,
although it was charred and friable, which by reason of its bad
conductivity of heat protected the roof boarding to such an extent
that it was "browned" only by the developed tar vapors. A fire was
next started within a building covered with a tar paper roof; the
flame touched the roof boarding, which partly commenced to char and
smoulder, but the bright burning of the wood was prevented by the
air-tight condition of the roof; the fire gases could not escape from
the building. The smoke collecting under the roof prevented the
entrance of fresh air, in consequence of which the want of oxygen
smothered the fire. The roofing paper remained unchanged. By making