Sewage and sewerage of farm homes [1922]Warren, George M. (George Milton)
Science
Sewage and sewerage of farm homes [1922]
Warren, George M. (George Milton)
Sewage disposal, Rural; Sewerage, Rural
[Illustration: Fig. 31.--Close soils should be deeply subsoiled and
underdrained. Porous, well-drained, air-filled soil is absolutely
necessary. _A_, Subsoiled ground; _B_, 3 or 4 inch distribution tile;
_C_, depth variable with the climate, 1-1/4 to 3-1/2 feet; _D_, 4-inch
underdrain; _E_, depth such as would prepare land for good crop
production, generally 3-1/2 to 4 feet; _F_, stone or other coarse
material; _G_, gravel grading upward to coarse sand; _H_, loose soil.]
Type 1 consists of a single box, into which all the lateral distributors
head. It will be noted that the laterals enter at slightly different
elevations, the two opposite the inlet sewer being the highest, the next
two slightly lower, and the next two the lowest. This staggering of the
outlets, in a measure, offsets the tendency of the flow to shoot across
and escape by the most direct route.
Type 2 calls for one or more diverting boxes, according to the number of
lateral distributors, and readily permits of wasting sewage at widely
separated elevations and distances. The outlet pipes enter the box at
slightly different elevations, for the reason already stated. With either
type, should the outlets not be set at the right elevations, partial
plugging of the holes and a little experimenting will enable one to
equalize or proportion the discharges.
[Illustration: Fig. 32.--Two systems of distribution on steep slopes--use
of diverting box. _A_ Direction of slope; _B_, contour of field; _C_,
4, 5 or 6 inch sewer from tank; _D_ diverting box; _E_, 3-inch or 4-inch
distribution tile.]
=Sewage switch.=--The clogging of filters and soils after long-continued
application of sewage has been previously referred to. It is, therefore,
desirable to arrange the distribution system in two units with a switch
between them, so that one area may drain and become aerated while the
other is in use. This procedure is especially desirable where the soil is
close and the installation of considerable size. It adds to the life and
effectiveness of the distribution area and permits use of a plant in case
it is necessary to repair, extend, or relay the tile in either unit.
Arrangement in two units does not necessarily mean doubling the amount
of tile and the area required in a single field. However desirable that
may be, expense or lack of suitable ground will often prevent. With open
sands and gravels and the assumed siphon dose of 20 gallons per person,
15 to 20 feet of 4-inch tile in each unit for each person will usually
suffice. With more compact soil it is advisable to more nearly double the
requirements previously described. Two simple types of switch are shown in
figure 33. The switch should be turned frequently, certainly as often as
is necessary to prevent saturation or bogginess of either area.