For the same reason as before, the copper conductor employed in the
Cable was not a solid rod, but a strand, composed of seven wires, each
of which gauged ·048 parts of an inch. It was found practically that
this form of conductor, in which six of the wires were laid in a spiral
direction around the seventh, was a most effectual protection against
the sudden or complete severance of the copper wire.
The severance, or “breach of continuity,” as it is usually called, is
one of the most serious accidents that can happen to a submerged Cable,
when unaccompanied by loss of insulation--owing to the great difficulty
in discovering the locality of such a fault. Even the best description
of copper wire can seldom be relied upon for equality of strength
throughout, and in some instances an inch or even a less portion of the
wire will prove to be slightly crystallised, and consequently incapable
of resisting the effects of coiling or paying out if brought to bear
upon the part, though no external difference be at all apparent between
the weak portion and the remainder of the sample. By proceeding,
however, as in the present case, the conductor was divided into seven
sections, and the risk of seven weak places occurring in the same spot
being exceedingly remote, the probability of a breach of continuity in a
strand conductor was almost _nil_.
The weight of the new conductor was nearly three times that of the
former one--being 300 pounds to the nautical mile against 107 pounds per
knot to the conductor of 1857. The adoption of this increased weight had
reference to the increase of commercial speed in the working of the new
Cable expected to accrue therefrom, and was founded upon the principles
of conduction and induction, now well understood, which consist in the
law that the conductivity of the conductor is as its sectional area,
while its inductive capacity (whereby speed of transmission is retarded)
is as its circumference only; and, as the maximum speed at which the
original Cable was ever worked did not exceed two and a-half words per
minute, it would follow by calculation, taking into account the
thickness of the dielectric surrounding the present conductor, that,
using the same instruments as in 1858, a speed of three and a-half to
four words per minute might be expected from the new Cable; but it was
stated by the electricians that owing to the improved modes of working
long Cables that have been discovered since 1858, an increase of speed
up to six or even more words per minute might be secured by the adoption
of suitable apparatus.
The purity of the copper employed, a very important item, affecting the
rate of transmission, had been carefully provided for. Every portion of
the conductor was submitted to a searching test, and all copper of a
lower conductivity than 85 per cent. of that of pure copper was
carefully rejected.