The Elements of Bacteriological Technique: A Laboratory Guide for Medical, Dental, and Technical Students. Second Edition Rewritten and Enlarged.Eyre, J. W. H. (John William Henry)
Science
The Elements of Bacteriological Technique: A Laboratory Guide for Medical, Dental, and Technical Students. Second Edition Rewritten and Enlarged.
Eyre, J. W. H. (John William Henry)
Bacteriology -- Technique
2. Remove the tube cultivation from its rack or jar with the
left hand and ignite the cotton-wool plug by holding it to
the flame of the Bunsen burner. Extinguish the flame by
blowing on the plug, whilst rotating the tube on its long
axis, its mouth directed vertically upward, between the
thumb and fingers. (This operation is termed "flaming the
plug," and is intended to destroy any micro-organisms that
may have become entangled in the loose fibres of the
cotton-wool, and which, if not thus destroyed, might fall
into the tube when the plug is removed and so accidentally
contaminate the cultivation.)
3. Hold the tube at or near its centre between the ends of
the thumb and first two fingers of the left hand, and allow
the sealed end to rest upon the back of the hand between the
thumb and forefinger, the plug pointing to the right. Keep
the tube as nearly in the horizontal position as is
consistent with safety, to diminish the risk of the
accidental entry of organisms (Fig. 68).
4. Take the handle of the loop between the thumb and
forefinger of the right hand, holding the instrument in a
position similar to that occupied by a pen or a paint-brush,
and sterilise the platinum portion by holding it in the
flame of a Bunsen burner until it is red hot. Sterilise the
adjacent portion of the aluminium handle by passing it
rapidly twice or thrice through the flame. After sterilising
it, the loop must not be allowed to leave the hand or to
touch against anything but the material it is intended to
examine, until it is finished with and has been again
sterilised.
5. Grasp the cotton-wool plug of the test-tube between the
little finger and the palm of the right hand (whilst still
holding the loop as directed in step 4), and remove it from
the mouth of the tube by a "screwing" motion of the right
hand.
6. Introduce the platinum loop into the tube and hold it in
this position until satisfied that it is quite cool. (The
cooling may be hastened by touching the loop on one of the
drops of moisture which are usually to be found condensed on
the interior of the glass tube, or by dipping it into the
condensation water at the bottom; at the same time care must
be taken in the case of cultures on solid media to avoid
touching either the medium or the growth.)
7. Remove a small portion of the growth by taking up a drop
of liquid, in the case of a fluid culture, in the loop; or
by touching the loop on the surface of the growth when the
culture is on solid medium; and withdraw the loop from the
tube without again touching the medium or the glass sides of
the tube.
8. Replace the cotton-wool plug in the mouth of the tube.
9. Replace the tube cultivation in its rack or jar.