The first few major bridges beyond the line's starting point on Pratt
Street, in Baltimore, were of rather elaborate masonry, but this may be
explained by the projectors' consciousness of the railroad's
significance and their desire for permanence. However, the
aforementioned economic factors shortly made obvious the necessity of
departure from this system, and wood was thereafter employed for most
long spans on the line as far as Harpers Ferry and beyond. Only the most
minor culverts and short spans, and those only in locations near
suitable quarries, were built of stone.
In addition to the economic considerations which prompted the company to
revert to timber for the major bridges, there were several situations in
which masonry construction was unsuitable for practical reasons. If
stone arches were used in locations where the grade of the line was a
relatively short distance above the surface of the stream to be crossed,
a number of short arches would have been necessary to avoid a very flat
single arch. In arch construction, the smaller the segment of a circle
represented by the arch (that is, the flatter the arch), the greater the
stress in the arch ring and the resulting horizontal thrust on the
abutments.
[Illustration: Figure 9.--BOLLMAN SKEW BRIDGE at Elysville (now
Daniels), Maryland, built in 1853-1854. (_Photo courtesy of Maryland
Historical Society._)]
The piers for the numerous arches necessary to permit an optimum amount
of rise relative to the span would have presented a dangerous
restriction to stream flow in time of flood. By the use of timber
trusses such crossings could be made in one or two spans with, at the
most, one pier in the stream, thus avoiding the problem.
The principal timber bridges as far west as Cumberland were of Latrobe's
design. These were good, solid structures of composite construction, in
which a certain amount of cast iron was used in joints and wrought iron
for certain tension members. They were, however, more empirical than
efficient and, for the most part, not only grossly overdesigned but of
decidedly difficult fabrication and construction.