The Preparation of Plantation RubberMorgan, Sidney
Science
The Preparation of Plantation Rubber
Morgan, Sidney
Rubber
VACUUM DRIERS.--The vacuum drier is so well known that only a brief
description need be given. It consists of a chamber heated by steam pipes
and capable of having the contained air and moisture withdrawn by a pump.
This description sounds very simple, and in practice the operation of
vacuum drying is really a simple one, and can well be entrusted to an
intelligent coolie under efficient supervision. Indicators are fitted which
show the vacuum pressure and the pressure of steam in the heating pipes
which travel underneath horizontal slabs upon which trays may be placed.
Still, in spite of the apparent simplicity of the process, there would
appear to be a number of little details which, if overlooked, prove to be
factors influencing the result to a considerable degree. Thus it is not
uncommon to find complaints that the rubber is not dry when packed. The
writers have seen rubber taken from a vacuum drier still containing a
visible quantity of moisture. One would have imagined that continuous
working of the drier would give the experience necessary to obtain dry
rubber, but, apparently, such is not the case in a number of instances.
Elaborate instructions are given by the makers, but often they are more
honoured in the breach than in the observance. Really, there are only two
points to bear in mind:
(1) That the rubber must be fairly thin.
(2) That the temperature be not allowed to rise too high. Some makers
advise 140° F. as a maximum, but no harm results from a temperature of
150° to 160° as long as the interval is not prolonged.[11]
[11] These figures refer to temperatures recorded by thermometers placed in
the folds of the rubber.
These two points presume that the vacuum drier is true to its name, and
that one can obtain a maximum steady pressure. The machines are so well
made now that no drier should be taken over from those responsible for its
erection unless it can show a vacuum pressure of 28 inches within fifteen
minutes of starting the pump; and with the pump stopped, there should not
be a greater fall in pressure than 1 inch within ten minutes after stopping
the pump.