The Turkish Bath, Its Design and ConstructionAllsop, Robert Owen
Science
The Turkish Bath, Its Design and Construction
Allsop, Robert Owen
Baths, Turkish
The method of constructing a furnace suitable for a small public bath
is, however, shown at Fig. 6. The excavations for stokery and heating
chamber being completed, and the position of the furnace determined a
solid foundation of concrete must be prepared, upon which the brickwork
to support the stove must be laid. At the same time, the foundations for
walls of furnace chamber, stokery, coke store, and the side walls for
the horizontal cold-air conducting flues will be prepared. These latter
must then be built in half-brick with glazed interior face, and the
furnace inclosed in similar work, as shown in perspective sketch. The
flues must be covered with York stone slabs 3 in. thick, up to within
three inches or so of the convolutions of the stove, at which distance
the side walls of the furnace must be erected, the back one similarly,
and the front one round the four projecting doors, which are,
respectively, the ash-pit door, the fire door, and two doors for
cleansing the horizontal smoke-box and interior of convolutions. The
furnace walls must be continued up to a few inches above the bend of
iron smoke flue, and then--if, as shown, the furnace be small--covered
with a 4-in. York slab in one piece. If the furnace be large, a flat
brick arch must form the covering, as at Fig. 8, where this arch
supports the flooring of the laconicum. The openings for the admission
of the heated air into the conduit leading into the hot rooms may be
either directly above, as shown in the last-named illustration, or in
the side, as in Fig. 6, with inclined flues. As a rule, it is more
economical, in heating on the principle now under consideration, to
place the furnace below the level of the hot rooms; but if desirable to
place both on one level, the back wall of the furnace chamber becomes
the party wall of the laconicum, and it must be stopped short of the
ceiling, and the air debouched over it.
In cheap baths the interior face of furnace chamber may be of stock
brickwork; but best glazed work should be adopted in good ones. All hot
and cold-air ducts should be similarly lined with glazed ware. In
first-class work the floors of horizontal and inclined flues should be
of white glazed tiles set in cement. Manholes must be provided for
cleaning when necessary. Every portion of furnace chamber, flues,
shafts, and conduits for hot and cold air must be "get-at-able" either
by means of manholes or by long brushes. Air-tight doors must be
indicated on the plans wherever this necessity demands them.
The iron smoke-pipe from furnace must be conducted to the smoke flue,
and the connection between furnace chamber and flue hermetically sealed.
The walls for a small furnace chamber need not be more than 4-1/2 in.
thick. Large furnaces require walls one-brick thick.
[Illustration: FIG. 7.
An Air Filter.]
Public-domain text, read in full here on John Shaqi.