Optical pyrometers are often used where it is impracticable to
use the thermo-couple, either because the temperature is so high
that it would destroy the couple, or the heat to be measured is
inaccessible to the couple of ordinary length. The temperatures of
slag or metal in furnaces or running through tap-holes or troughs
are often measured with optical pyrometers.
In one type of optical pyrometer, the observer focuses it on the
metal or slag and moves an adjustable dial or gage so as to get
an exact comparison between the color of the heat measured with
the calor of a lamp or screen in the pyrometer itself. This, of
course, requires practice, and judgment, and brings in the personal
equation. With care, however, very reliable temperature measurements
may be made. The temperatures of rails, as they leave the finishing
pass of a rolling mill, are measured in this way.
Another type of optical pyrometer is focused on the body, the
temperature of which is to be measured. The rays converge in the
telescope on metal cells, heating them, and thereby generating a
small electric current, the voltage of which is read an a calibrated
voltmeter similar to that used with the thermo-couple. The best
precision is obtained when an optical pyrometer is used each time
under similar conditions of light and the same observer.
Where it is impracticable to use either thermo-couples or optical
pyrometers, "sentinels" may be used. There are small cones or cylinders
made of salts or other substances of known melting points and covering
a wide range of temperatures.
If six of these "sentinels," melting respectively at 1,300 deg., 1,350 deg.,
1,400 deg., 1,450 deg., 1,500 deg., and 1,550 deg.F., were placed in a row in a
furnace, together with a piece of steel to be treated, and the
whole heated up uniformly, the sentinels would melt one by one and
the observer, by watching them through an opening in the furnace,
could tell when his furnace is at say 1,500 deg. or between 1,500 deg. and
1,550 deg., and regulate the heat accordingly.
A very accurate type of pyrometer, but one not so commonly used as
those previously described, is the resistance pyrometer. In this
type, the temperature is determined by measuring the resistance to an
electric current of a wire which is at the heat to be measured. This
wire is usually of platinum, wound around a quartz tube, the whole
being placed in the furnace. When the wire is at the temperature of
the furnace, it is connected by wires with a Wheatstone Bridge, a
delicate device for measuring electrical resistance, and an electric
current is passed through the wire. This current is balanced by
switching in resistances in the Wheatstone Bridge, until a delicate
electrical device shows that no current is flowing. The resistance
of the platinum wire at the heat to be measured is thus determined
on the "Bridge," and the temperature read off on a calibration
chart, which shows the resistance at various temperatures.