Transactions of the American Society of Civil Engineers, vol. LXX, Dec. 1910: Tests of Creosoted Timber, Paper No. 1168Gregory, W. B. (William Benjamin)
Science
Transactions of the American Society of Civil Engineers, vol. LXX, Dec. 1910: Tests of Creosoted Timber, Paper No. 1168
Produced by Juliet Sutherland, Sigal Alon and the Online
Distributed Proofreading Team at http://www.pgdp.net
[Transcriber's Note:
1. Mathematical power (superscript) is rendered using a carat (^).
2. Superscript text is rendered using an underscore (_).]
AMERICAN SOCIETY OF CIVIL ENGINEERS
INSTITUTED 1852
TRANSACTIONS
Paper No. 1168
TESTS OF CREOSOTED TIMBER.
BY W. B. GREGORY, M. AM. SOC. C. E.
During the last few years a quantity of literature has appeared in which
the treatment of timber by preservatives has been discussed. The
properties of timber, both treated and untreated, have been determined
by the Forest Service, United States Department of Agriculture, and
through its researches valuable knowledge has come to engineers who have
to deal with the design of wooden structures. There is very little
information, however, regarding the effect of time on creosoted timber,
and for this reason the results given herewith may prove of interest.
The material tested consisted of southern pine stringers having a
cross-section approximately 6 by 16 in. and a length of 30 ft. For the
purpose of testing, each beam was cut into two parts, each about 15 ft.
long. This material had been in use in a trestle of a railroad near New
Orleans for 26 years. The stringers were chosen at random to determine
the general condition of the trestle. The timber had been exposed to the
weather and subjected to heavy train service from the time it was
treated until it was tested. The annual rainfall at New Orleans is about
60 in., and the humidity of the air is high. In spite of these
conditions, there was no appearance of decay on any of the specimens
tested. The specifications under which the timber was treated were as
follows:
TIMBER.
The timber for creosoting shall be long-leafed or southern pine. Sap
surfaces on two or more sides are preferred.
_Piles._--The piles shall be of long-leafed or southern pine, not less
than 14 in. at the butt. They shall be free from defects impairing their
strength, and shall be reasonably straight.
The piles shall be cleanly peeled, no inner skin being left on them. The
oil used shall be so-called creosote oil, from London, England, and
shall be of a heavy quality.
The treatment will vary according to the dimensions of the timbers and
length of time they have been cut. Timbers of large and small dimensions
shall not be treated in the same charge, neither shall timbers of
differing stages of air seasoning, or the close-grained, be treated in
the same charge with coarse or open-grained timbers.
The timbers shall be subjected first to live steam superheated to from
250 to 275 deg. Fahr., and under a 30 to 40-lb. pressure. The live steam
shall be admitted into the cylinders through perforated steam pipes, and
the temperature shall be obtained by using superheated steam in closed
pipes in the cylinders.