The early form of Solar Radiation Thermometer was a self-registering
maximum thermometer, with blackened bulb, having its graduated _stem_,
only, enclosed in an outer tube. Errors arising from terrestrial
radiation and the _variable_ cooling influences of aërial currents are
all obviated in the improved and patented Solar Radiation Thermometer
shown at Fig. 3, which consists of a self-registering maximum
thermometer, having its _bulb and stem_ dull-blackened, in accordance
with the suggestion of the Rev. F. W. Stow, and the _whole_ enclosed in
an outer chamber of glass, from which the air has been completely
exhausted. The perfection of the vacuum in the enclosing chamber is
proved by the production of a pale white phosphorescent light, with
faint stratification and transverse bands when tested by the spark from
a Ruhmkorff coil. Due provision is made for this by the attachment of
platinum wires to the lower side of the tube, and when tested by a
syphon pressure gauge, the vacua have been proved to exist to within
1/50th of an inch of pressure. It will thus be seen that the
indications are preserved from errors arising from atmospheric
currents, and from the absorption of heat by aqueous or other vapours,
the whole of the solar heat passing through the vacuum direct to the
blackened bulb. The contained mercury expanding, carries the recording
index to the highest point, and thus is obtained a registration of the
maximum amount of solar radiation during the twenty-four hours. The
great advantage accruing from the high degree of perfection to which
this instrument has been brought is, _uniformity_ of construction,
which renders the observations made at different stations
_intercomparable_. An enlarged view of the thermometer is given at Fig.
3, showing the platinum wire terminations, whereby the vacuum is
tested. The Rev. Fenwick W. Stow thus directs the manner in which the
solar radiation thermometer should be used:—
1. Place the instrument four feet above the ground, in an open space,
Fig. 4, with its bulb directed towards the S.E. It is necessary that
the globular part of the external glass should not be placed in contact
with or very near to any substance, but that the air should circulate
round it freely. Thus placed, its readings will be affected only by
direct sunshine and by the temperature of the air.
2. One of the most convenient ways of fixing the instrument will be to
allow its stem to fit into and rest upon two wooden collars fastened
across the ends of a narrow slip of board, which is nailed in its
centre upon a post steadied by lateral supports (Fig. 4).
3. The maximum temperature of the air in shade should be taken by a
thermometer placed on a stand in an open situation. Any stand which
thoroughly screens it from the sun, and exposes it to a free
circulation of air, will do for the purpose.
4. The difference between the maxima in sun and shade, thus taken, is a
measure of the amount of solar radiation.
Public-domain text, read in full here on John Shaqi.