Webster's practical forestry : $b A popular handbook on the rearing and growth of trees for profit or ornamentWebster, Angus D.
Science
Webster's practical forestry : $b A popular handbook on the rearing and growth of trees for profit or ornament
Webster, Angus D.
Forests and forestry -- Great Britain; Trees -- Great Britain
The straining-posts are placed in the ground at 150 yards apart, with
an additional strong post at every angle or curve that occurs in the
line of fence. The intermediate posts are pointed and driven into the
ground along the line of fence at 6 ft. apart.
In order to make a fence proof against the inroads of sheep and cattle
not less than six wires should be erected, and galvanized strand wire
is preferable. The total height of the fence need not exceed 3 ft. 6
in., and the top wires should be placed farther apart than those lower
down.
In tightening the wires a straining machine is usually employed, but
brackets for the same purpose are preferable, these being attached to
the straining-posts.
They are of particular value, as the wire can be tightened or slackened
at will.
The posts should be rounded on the top or sawn with a slant, so that
the rain may run off.
=Draining the Ground.=—Efficient drainage must be considered as one of
the most important operations in the formation of a plantation. Every
portion of the ground may not, probably, require to be drained, but
where it is at all surcharged with moisture the removal of such will be
a step in the right direction if the future welfare of the trees is a
point of first importance. In commencing draining the position of the
main outlet must first be determined, and in doing so every fall of
the ground should be taken advantage of. It is quite impossible to lay
down rules as to the number, sizes, and distances apart of the various
drains, these being points that can only be satisfactorily settled
on the spot, and when the nature of the soil, lie of the ground, and
amount of rainfall to be carried off are determined. In most cases,
however, the main drains should be from 2 ft. 6 in. to fully 3 ft. wide
at the top or surface, from 10 in. to 12 in. wide at the bottom, and
about 3 ft. deep. The minor drains may be less in proportion to the
mains, and are usually 2 ft. deep, 2½ ft. wide at top, and the width of
the draining spade at bottom.
According to the nature of the ground so will the distances at which
the drains should be cut vary, but in most cases from 15 ft. to 30 ft.,
sometimes even less, and sometimes considerably more. The minor drains
should never run at right angles to the main, but at about 45°, which
will prevent the mouths becoming choked up when there is a rush of
water in the main. The soil removed from the drains should be evenly
spread out over the ground-surface.
[Illustration: TOOLS USED IN DRAINING]
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account