Figure 9 shows a sodium iodide crystal used to react with the gamma rays
that traverse it. To the left of the crystal is a cluster of seven
photomultiplier tubes that “watch” for the scintillations, convert them
to electrical pulses, and amplify them so they can be sorted, counted,
and recorded. A trace of thallium added to the sodium iodide improves
its scintillation properties.
In addition to being of convenient size and easy to maintain, crystal
detectors have another advantage over liquid systems. The energy of the
incident gamma rays from crystals is more accurately indicated by the
quality of the flashes of light impinging on the photomultiplier tubes.
If two or more radionuclides are emitting gamma rays, a crystal detector
distinguishes between their energy levels with much more precision and
sensitivity than does a liquid system. Crystal instruments separate
gamma rays differing by no more than 0.05 Mev.
The energies of the gamma rays emitted by nuclides have all been
determined and are listed in handbooks. A scientist can thus identify
the data delivered by a multichannel pulse-height analyzer as coming
from potassium-40, zinc-65, or any other nuclide.
Counters using sodium iodide crystals intercept, and therefore count, a
much smaller fraction of the gammas emitted by the subject’s body than
liquid systems, but they also pick up a smaller amount of background.
When speed is important, the liquid counter is more effective, but the
crystal counter is preferred when radionuclides emitting gammas of
nearly the same energies are to be separated and counted.
THE RADIUM STORY
Radium-226 in the human body poses unique problems for whole body
counters. People who have accumulated this nuclide only because of the
minute amounts occurring naturally in food and water have counts of only
two or three disintegrating atoms per second, and this amount cannot be
distinguished from background radiation. Whole body counters are useful,
however, in diagnosing effects in persons who have been overexposed to
radium. These include persons who formerly were employed to paint watch
dials with a luminous paint containing radium. (See table below.)
[Illustration: Figure 10 _A group of radium dial painters at work in a
watch factory in 1922. Almost all these employees have been identified
and the living ones recently have participated in a study at Argonne
National Laboratory to determine the extent of radium accumulation in
their bodies. Whole body counters aided in their examinations._]
Excerpts from case records of one research center show the high counts
found in several patients and the source of the radium or thorium (a
closely related element) that their bodies had taken up: