“Like a child which hides behind a wooden door to shield itself from
the bullets of a machine gun, our young radiologists believe they are
safe when they have donned their gloves and examine their patients
behind a sheet of lead glass. But, unfortunately, these enable them
only to avoid those superficial skin affections caused by the most
absorbable rays of the spectrum.
“But they receive, alas, those other radiations which are more
penetrating, and these slowly produce lesions of all the ductless
glands in the body, whose internal secretions we now know to be of such
vital importance in the bodily economy.”
The modern employment of 200,000 volts under three milliamperes gives
rise to the need of great caution in the use of X-rays. Even the
health of persons in adjoining rooms or buildings, Dr. Contremoulins
believes may be imperiled. In the _Popular Science Monthly_ for
October, 1921, this veteran radiologist makes some startling
revelations. To quote a few passages:
“In April, 1896, five months after the discovery of X-rays—or Roentgen
rays, as they are also named in honor of their discoverer—a pose of
eight hours was required for a correct radiograph of a profile head,
the tube being placed ten inches from the sensitive plate.
“In April, 1921, a similar image was obtained in four hours at a
distance of 90 yards from the apparatus. This means that the radiation
with modern apparatus is more than 20,000 times stronger than was
possible in 1896.
“With the very weak radiation that I have used for my experiments,
corresponding to the ordinary radiographic and radioscopic work, it has
been easy for me to obtain images of metallic objects and human bones
placed on a sensitive plate 15 feet from the radiating source, although
the rays pass directly through a slab of marble an inch thick, a sheet
of lead one-tenth of an inch thick, and a flooring eight inches deep,
built of oak boards and rough plaster.
“Fifty feet from this same source I have been able in four hours to fog
a photographic plate placed behind a wall of brick and stone 20 inches
thick. Also in the same time I have obtained a correct radiograph
of a skull and a crab, 262 feet from the X-ray machine. All these
experiments were made with a 17-centimeter spark and two milliamperes
of current.
“If photographic plates are so readily affected by these rays, we must
admit that animal cells also are affected to an appreciable degree.
The X-rays that are being used to cure a patient may at the same time
inflict radio-dermatitis on other persons exposed to their influence in
adjoining rooms or buildings. Nothing will suffice for safety but to
cover the walls and floors of X-ray rooms with sheets of lead from a
quarter to half an inch thick, according to the power of the source and
its distance from the lining....
Public-domain text, read in full here on John Shaqi.