A Manual of Clinical DiagnosisTodd, James Campbell
Science
A Manual of Clinical Diagnosis
Todd, James Campbell
Diagnosis, Laboratory
Excretion of chlorids is diminished in nephritis and in fevers,
especially in pneumonia and inflammations leading to the formation of
large exudates. In nephritis the {57} kidneys are less permeable to
the chlorids, and it is probable that the edema is due largely to an
effort of the body to dilute the chlorids which have been retained. In
fevers the diminution is due largely to decrease of food. In pneumonia
chlorids are constantly very low, and in some cases are absent
entirely. Following the crisis they are increased. In inflammations
leading to formation of large exudates--_e.g._, pleurisy with
effusion--chlorids are diminished, because a considerable amount
becomes "locked up" in the exudate. During absorption chlorids are
liberated and appear in the urine in excessive amounts.
[Illustration: FIG. 16.--The Purdy electric centrifuge.]
_Quantitative Estimation_.--The best method for clinical purposes is
the centrifugal method.
{58} _Purdy's Centrifugal Methods_.--As shown by the late Dr. Purdy,
the centrifuge offers an important means of making quantitative
estimations of a number of substances in the urine. Results are easily
and quickly obtained, and are probably accurate enough for all
clinical purposes.
[Illustration: FIG. 17.--Water-motor centrifuge.]
In general, the methods consist in precipitating the substance to be
estimated in a graduated centrifuge tube, and applying a definite
amount of centrifugal force for a definite length of time, after which
the percentage of precipitate is read off upon the side of the tube.
Albumin, if present, must be previously removed by boiling and
filtering. Results are in terms of _bulk of precipitate_, which must
not be confused with _percentage by weight_. The weight percentage can
be found by referring to Purdy's tables, given later. In this, as in
all quantitative urine work, percentages mean little in themselves;
the actual {59} amount eliminated in twenty-four hours should always
be calculated.
The centrifuge should have an arm with radius of 6¾ inches when in
motion, and should be capable of maintaining a speed of 1500
revolutions a minute. The electric centrifuge is to be recommended,
although good work can be done with a water-power centrifuge, or,
after a little practice, with the hand centrifuge. A speed indicator
is desirable with electric and water-motor machines, although one can
learn to estimate the speed by the musical note.
[Illustration: FIG. 18.--Purdy's tubes for the centrifuge: _a_,
Percentage tube; _b_, sediment tube.]
* * * * *
Public-domain text, read in full here on John Shaqi.