Many devices have been described by the use of which the electrode
upon which deposition occurs can be mechanically rotated. This has an
effect parallel to that of greatly increasing the electrode surface
and also provides a most efficient means of stirring the solution.
With such an apparatus the amperage may be increased to 5 or even 10
amperes and depositions completed with great rapidity and accuracy. It
is desirable, whenever practicable, to provide a rotating or stirring
device, since, for example, the time consumed in the deposition of the
amount of copper usually found in analysis may be reduced from the
20 to 24 hours required with stationary electrodes, and unstirred
solutions, to about one half hour.
DETERMINATION OF COPPER AND LEAD
PROCEDURE.--Weigh out two portions of about 0.5 gram each (Note 1)
into tall, slender lipless beakers of about 100 cc. capacity. Dissolve
the metal in a solution of 5 cc. of dilute nitric acid (sp. gr. 1.20)
and 5 cc. of water, heating gently, and keeping the beaker covered.
When the sample has all dissolved (Note 2), wash down the sides of the
beaker and the bottom of the watch-glass with water and dilute the
solution to about 50 cc. Carefully heat to boiling and boil for a
minute or two to expel nitrous fumes.
Meanwhile, four platinum electrodes, two anodes and two cathodes,
should be cleaned by dipping in dilute nitric acid, washing with water
and finally with 95 per cent alcohol (Note 3). The alcohol may be
ignited and burned off. The electrodes are then cooled in a desiccator
and weighed. Connect the electrodes with the binding posts (or other
device for connection with the electric circuit) in such a way that
the copper will be deposited upon the electrode with the larger
surface, which is made the cathode. The beaker containing the solution
should then be raised into place from below the electrodes until the
latter reach nearly to the bottom of the beaker. The support for the
beaker must be so arranged that it can be easily raised or lowered.
If the electrolytic apparatus is provided with a mechanism for the
rotation of the electrode or stirring of the electrolyte, proceed as
follows: Arrange the resistance in the circuit to provide a direct
current of about one ampere. Pass this current through the solution
to be electrolyzed, and start the rotating mechanism. Keep the beaker
covered as completely as possible, using a split watch-glass (or other
device) to avoid loss by spattering. When the solution is colorless,
which is usually the case after about 35 minutes, rinse off the cover
glass, wash down the sides of the beaker, add about 0.30 gram of urea
and continue the electrolysis for another five minutes (Notes 4 and
5).