Auroræ: Their Characters and SpectraCapron, J. Rand
History
Auroræ: Their Characters and Spectra
Capron, J. Rand
Auroras
[Sidenote: Tube No. 1 between the poles of the magnet. Change of colour
in capillary stream. “Tailing-over” of capillary stream.]
(3) The capillary part of tube No. 1 was arranged between the poles of
Ladd’s electro-magnet, the conical ends of the armatures almost touching
the tube (Plate XVII. fig. 1). With the magnet not excited, the capillary
stream was bright and of a slightly rosy-yellow tinge. It varied a little
in apparent diameter with the current. As soon as the magnet was excited
the capillary stream, as also (in a less degree) that in the bulbs,
were seen to contract, and to change from a _rosy_ tint to a distinctly
_blue-violet_. The polished armatures, acting as reflectors, showed this
change of tint in a most marked manner each time the magnet was excited.
At the same time the capillary stream was seen to run into the negative
bulb, as if overflowing, and with an effect resembling the “tailing-over”
of a gas-flame. This effect took place each time the magnet was excited,
and was not found at the positive-bulb end.
[Sidenote: Spectrum examined.]
Occasionally, when the magnet was excited, flashes of light were
discharged in the negative bulb from the capillary towards the
violet-pole. The spectrum was then carefully examined. No change was
seen in the actual position of any of the lines or bands when the tube
was influenced by the magnet, but those towards the violet end of the
spectrum were conspicuously brightened.
[Sidenote: Negative bulb between poles of the magnet. Positive bulb
within action of the magnet.]
(4) The extremity of the negative bulb was now placed between the poles
of the magnet. A bright violet-coloured arc, following the magnetic
curve, was at once formed, as in the case of the large Plücker tubes; and
at the same time a straight stream of not very bright light ran along the
bulb. The positive bulb was next placed within the action of the magnet;
and immediately a brilliant spiral of flickering light appeared in the
bulb, lighting it up, and reminding one in shape of the spiral which
water forms on being poured from a lipped jug (see Plate XVII. fig. 9).
[Sidenote: Spiral formed.]
This was repeated each time the magnet was excited. The spiral, though
flickering in character, was permanent in form, and inclined to the side
of the tube which was in contact with the N pole of the magnet.
_Oxygen-tubes._
[Sidenote: O tube No. 1; spectrum described.]
A tube (No. 1) was lighted up and examined with the spectroscope, and
found to give the spectrum shown on Plate XIV. spectrum 3, but with a
strong set of H lines in addition.
[Sidenote: O tube No. 2; spectrum described.]
A second tube (No. 2) was then lighted up. The spectrum was a bright one,
similar to the foregoing, the principal H lines being present, but not
strong.
[Sidenote: Tube-glow described. Effect upon glow when magnet excited.
Bulbs between poles of the magnet. Effect of magnet on spectrum.]
Public-domain text, read in full here on John Shaqi.
Reviews
Reviews
No reviews yet
Be the first to share your thoughts on this work.
Elsewhere in the archive
Join the Discussion
Join the discussion
Sign in to leave a comment or review.
Sign InorCreate an account