As the magnetite arc requires direct current for its operation, the
obvious way to supply a direct constant current for series circuits
is to rectify, by means of the mercury arc, the alternating current
obtained from a constant current transformer. The terminals of the
movable secondary coil of the constant current transformer are
connected to the two arms of the rectifier tube. One end of the series
circuit is connected to the center of the secondary coil. The other
end of the series circuit is connected to a reactance which in turn
is connected to the pool of mercury in the bottom of the rectifier
tube. One-half of the cycle of the alternating current goes from the
secondary coil to one arm of the rectifier tube through the mercury
vapor, the mercury arc having already been started by a separate
starting electrode. It then goes to the pool of mercury, through
the reactance and through the series circuit. The other half cycle
of alternating current goes to the other arm of the rectifier tube,
through the mercury vapor, etc., and through the series circuit. Thus a
pulsating direct current flows through the series circuit, the magnetic
action of the reactance coil making the pulsations of current overlap
each other, which prevents the mercury arc from going out.
[Illustration: EARLY MERCURY ARC RECTIFIER INSTALLATION.]
INCANDESCENT LAMP DEVELOPMENTS, 1894–1904
With the development of a waterproof base in 1900, by the use of a
waterproof cement instead of plaster of Paris to fasten the base to
the bulb, porcelain at first and later glass being used to insulate
the terminals of the base from each other, lamps could be exposed to
the weather and give good results. Electric sign lighting therefore
received a great stimulus, and lamps as low as 2 candlepower for 110
volts were designed for this purpose. Carbon lamps with concentrated
filaments were also made for stereoptican and other focussing purposes.
These lamps were made in sizes from 20 to 100 candlepower. The arc lamp
was more desirable for larger units.
The dry battery was made in small units of 2, 3 and 5 cells, so that
lamps of about ⅛ to 1 candlepower were made for 2½, 3½ and 6½ volts,
for portable flashlights. It was not however until the tungsten
filament was developed in 1907 that these flashlights became as popular
as they now are. For ornamental lighting, lamps were supplied in round
and tubular bulbs, usually frosted to soften the light.
[Illustration: THE MOORE TUBE LIGHT, 1904.
This consisted of a tube about 1¾ inches in diameter and having a
length up to 200 feet, in which air at about one thousandth part
of atmospheric pressure was made to glow by a very high voltage