When the variations in the pressure upon the transmitter diaphragm
in either hand set varies the resistance of the corresponding branch
circuit a slight variation in the current from the battery is produced.
The internal resistance of the battery is sufficient to produce a
slight variation in its terminal voltage. The resulting variations in
the line voltage, and hence in the drop across the receivers, produce
the usual vibrations in the receiver diaphragms. These variations also
produce slight variations in the current through the primary winding
of the induction coil, resulting in greater variations across the
terminals of the secondary winding. Since the secondary winding is
in series with the battery, the practical effect is to amplify the
variations in the line voltage, and hence in the talking currents.
Successful working of the relays is obtained only by a careful
adjustment of the screws which regulate the throw of the armatures. The
relay “A” is located in front of the “+” battery post, the relay “C” in
front of the “G” post.
In addition to the above matériel there are necessary for the mine
system certain electrical instruments, as well as tools, appliances,
and supplies requiring no special description, which are enumerated in
the supply list. (Appendix 8.)
Figures 17a and 17b, at the end of the book, show the construction of
an improvised mine target.
CHAPTER III.
LOADING ROOM DUTIES.
=Making a telegraph joint.=—The insulation is removed from the ends for
1½ inches and the wires brightened. The ends to be joined are placed
across each other about one-third distance from the insulation, making
an angle of about 45° with each other. The wires are grasped firmly at
the junction and each free end wound tightly around the other wire for
four turns; the winding should be in opposite directions. The ends of
the wires are trimmed down so they will be smooth and present no sharp
points.
When wires are joined with brass jointers three-fourths inch of each
wire is bared and the wires are inserted in the jointer; each end is
crimped with pliers in the direction of the longer axis; the rest of
the jointer is crimped and the ends or sharp points rounded off. When
brass jointers are used care should be exercised not to crimp them
too hard, as the wires may be partly cut through and finally broken.
Special care must be used with the fuse leads, as the secondary circuit
of the mine transformer can not be tested after the compound plug is
assembled.