Portable Flame Thrower M2-2United States. War Department
History
Portable Flame Thrower M2-2
United States. War Department
Flame throwers -- Handbooks, manuals, etc.; United States. Army -- Equipment -- Handbooks, manuals, etc.
_a. Flame thrower._ One or more small-arms bullets through the fuel
tanks will prevent any immediate use of the flame thrower. Additional
rounds may be put through the pressure tank. If the pressure tank is
charged, the pressure-tank valve should be opened for a few seconds,
thus permitting the contents to dissipate. This is necessary if rounds
are to be fired point-blank. The gun may be rendered useless by bending
it over a hard object. A sledge or ax will demolish valves and tubes. A
fragmentation grenade will also achieve demolition.
_b. Filling and charging apparatus._ The flexible tubing, gages, and
valves may be destroyed by blows with an ax, sledge, or other heavy
instrument. The large pressure cylinders are rendered useless by
releasing the contents and then destroying the valves by blows with an
ax or sledge. Cylinders can be stacked like cordwood in groups of five
and demolished by the detonation of four 1/2-pound blocks (2 pounds) of
TNT in their midst. The air compressor may be destroyed by a similar
procedure.
_c. Fuel._ Burn.
_d. Mixing apparatus._ Containers and filling lines may be rendered
useless by ax or sledge blows, or by small-arms fire.
_e. Thickener._ Cans of thickener should be broken open. Contents
should be thrown into a fire or into a body of water.
_f. Ignition cylinders._ Burn to destroy. Personnel should stay
several yards from the fire because the cylinders ignite with a slight
detonation.
PART THREE
MAINTENANCE INSTRUCTIONS
Section XI GENERAL
47. SCOPE.
Part Three contains information for the guidance of the personnel of
the using organizations responsible for the maintenance (1st and 2nd
echelon) of this equipment. It contains information needed for the
performance of the scheduled lubrication and preventive maintenance
services as well as descriptions of the major systems and units and
their functions in relation to other components of the equipment.
Section XII SPECIAL ORGANIZATIONAL TOOLS AND EQUIPMENT
48. SERVICE KIT.
One service kit for portable flame thrower M2-2 will be furnished
for each six M2-2 portable flame throwers. The kit includes tools,
equipment, and spare parts for second echelon maintenance and for
pressure-tank charging. Adjustable wrenches may be included in place of
the plain-end wrenches listed. Numbers listed with items are Chemical
Warfare Service stock numbers. Approximate contents are as follows:
_a. Tools._
1 Screwdriver, cabinet, 4-1/2-inch blade length, 3/16-inch blade
diameter, H22-50-13. (Fig 8)
1 Screw driver, common, 6-inch blade length, 5/16-inch blade
diameter, H22-50-6. (Fig 8)
2 Wrenches, hex, 3/16 inch across flats (for 3/8-inch socket-head set
screws), H22-49-91.
2 Wrenches, hex, 1/8 inch across flats (for 1/4-inch socket-head set
screws), H22-49-12. (Fig 8)
1 Wrench, valve-adjusting, assembly A81-6-48. (Fig 8)
1 Wrench, heavy “S”, 1-3/8-inch and 1-1/2-inch openings, 12 inches
approx length, H22-49-113. (Fig 8)