Sewerage and Sewage TreatmentBabbitt, Harold E. (Harold Eaton)
History
Sewerage and Sewage Treatment
Babbitt, Harold E. (Harold Eaton)
Sewage disposal; Sewerage
FIG. 128.—Segmental Block Sewer at Clinton, Iowa.
]
=186. Organization.=—The number of men employed on a brick or block
sewer is proportioned according to the size of the sewer and the working
conditions. The number of men working on different tasks usually bears
the same ratio to the number of masons employed, regardless of the size
of the work. These proportions are shown for different jobs, in Table
66.
TABLE 66
ORGANIZATIONS FOR THE CONSTRUCTION OF BRICK AND BLOCK SEWERS
─────────────┬──────────────┬────────┬────────┬────────┬────────┬──────────
│ │ │ │ │ 84– to │
│General Ratio │15–foot,│66–inch │84–inch │108–inch│ 42–inch
Type of Work │ on Basis of │ 5–ring │Circular│Circular│ Sewer │Lock-Joint
│ Four Brick │ Brick, │ Brick, │ Brick, │Brick in│Tile Block
│ Layers │Chicago │ Gary │ Gary │Detroit │
│ │ │ │ │ Tunnel │
─────────────┼──────────────┼────────┼────────┼────────┼────────┼──────────
Foreman │ 1│ 1│ 1│ 1│ 1│ 1
Brick layers │ 4│ 12│ 6│ 6│ 5│ 2
Helpers │ 2│ 11│ 3│ 3│ │ 1
Scaffold men │ 2│ 21│ 3│ │ │
Brick tossers│ 2│ 7│ │ 15│ │ 2
Brick │ 2│ 2│ │ │ │ 2
carriers │ │ │ │ │ │
Cement mixers│ 2│ 6│ 6│ 5│ │ 1
Cement │ 2│ 10│ │ 8│ │
carriers │ │ │ │ │ │
Form setters │ 1│ │ 3│ 3│ │
Laborers │ 1│ 8│ 19│ 3│ 14│ 7
│ Municipal │
Source of │ Engineering, │ H. P. Gillette, Handbook of Cost Data
Information│ Vol. 54, p. │
│ 228 │
─────────────┴──────────────┴──────────────────────────────────────────────