Ignite and weigh a clean platinum dish, and measure into it 100 cc. of
the thoroughly shaken sample. Evaporate to dryness on a water bath. Then
heat the dish in an oven at 103° C. or 180° C. for one hour. Cool in a
desiccator and weigh. The temperature of drying should be mentioned in
the report. The increase in weight gives the total solids or residue on
evaporation. If 100 cc. of the sample was taken this weight expressed in
milligrams and multiplied by 10 is equal to parts per million of residue
on evaporation. The residue from waters low in organic matter but
relatively high in iron may be used, as a matter of convenience, for the
determination of iron.
FIXED RESIDUE AND LOSS ON IGNITION.[13][96]
The residue from sewages and waters high in organic matter may be
ignited to burn off the organic matter, which, with some volatile
inorganic matter, constitutes the loss on ignition.
_Procedure._—Ignite the residue in the platinum dish at a low red heat.
If great accuracy is desired this should be done in an electric muffle
furnace or in a radiator, which consists of a platinum or a nickel dish
large enough to allow an air space of about half an inch between it and
the dish within it, the inner dish being supported by a triangle of
platinum wire laid on the bottom of the outer dish. A disc of platinum
or nickel foil large enough to cover the outer dish is suspended over
the inner dish to radiate the heat into it. The larger dish is heated to
bright redness until the residue is white or nearly so. Allow the dish
to cool, and moisten the residue with a few drops of distilled water.
Dry the residue in the oven, cool in a desiccator, and weigh. The fixed
residue on evaporation is the difference between this weight and the
weight of the dish.
The loss on ignition is the difference between the total residue on
evaporation and the fixed residue on evaporation.
If the odor and color on ignition of some residues give helpful clues to
the character of the organic matter record them.
SUSPENDED MATTER.[56][110]
DETERMINATION WITH GOOCH CRUCIBLE.
_Reagent._—Prepare a dilute cream of asbestos fibre which has been
finely shredded, thoroughly ignited, treated with strong hydrochloric
acid for at least 12 hours, and washed with distilled water till free
from acid.
_Procedure._—1. Prepare a mat of the asbestos fibre 1/16 inch thick in a
Gooch crucible. Dry it in an oven at 103 or 180° C., cool and weigh.
Filter 1,000 cc. of samples having a turbidity of 50 parts per million
or less. If the turbidity is higher use sufficient water to obtain 50 to
100 mg. of suspended matter. Dry for one hour at 103 or 180° C., cool
and weigh. Report the temperature at which the residue was dried. If
1,000 cc. is filtered the increase in weight expressed in milligrams is
equal to parts per million of suspended matter.
DETERMINATION BY FILTRATION.